Skip to main content
Schneider Electric EZC400H44320N

Schneider Electric EZC400H44320N EasyPact EZC400H 400 A 4P M

MPN EZC400H44320N
Obsolete

Schneider Electric EasyPact EZC400H series, EZC400H44320N, 4P moulded-case circuit breaker, 400 A rated current at 40 °C, 50 kA Icu at 400 V AC, thermal-magnetic TM-D trip unit, fixed mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC400H44320N key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC400H44320N additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width140 mm
Height255 mm
Electrical life cyclesCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC400H44320N is a 4-pole moulded-case circuit breaker from the EasyPact EZC400H series, rated 400 A at 40 °C with a thermal-magnetic TM-D trip unit. Breaking capacity hits 50 kA Icu at 400–415 V AC 50/60 Hz per IEC 60947-2, and 70 kA Icu at 220–240 V AC. The magnetic trip is fixed at 3200 A, so it clears short-circuit faults fast — no adjustable instantaneous pickup on this unit.

Selectivity and SCCR headroom

With 50 kA Icu across the 400–440 V range (and 70 kA at 240 V), this breaker coordinates well upstream of smaller panel feeders. The TM-D trip is thermal-magnetic, so overload curve follows the bimetal; short-circuit is magnetic-only at 8× In (3200 A). That fixed magnetic ratio limits selectivity with downstream breakers that have lower instantaneous thresholds — plan coordination studies if feeding multiple panelboards.

Fixed backplate mounting, 45 mm pole pitch. The 140 mm width and 255 mm height fit standard distribution panel cutouts; depth is 140 mm. Toggle handle with positive contact indication gives visual confirmation of contact position. No earth-leakage module fitted (specified as 'Without'), so external RCD or RCBO is needed if ground-fault protection is required.

MPN
EZC400H44320N