Skip to main content
Schneider Electric EZC400N3300

Schneider Electric EZC400N3300 EasyPact EZC400N, 400 A, 3P,

MPN EZC400N3300
Obsolete

Schneider Electric EasyPact EZC400N, EZC400N3300, 3-pole molded case circuit breaker, 400 A rated at 40 °C, 36 kA Icu at 440 V AC, TM-D thermal-magnetic trip unit, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC400N3300 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch44 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC400N3300 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width185 mm
Height255 mm
Electrical life cyclesCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

If your enclosure runs hotter, the TM-D thermal-magnetic trip unit will derate; the trip unit itself is rated 300 A at 50 °C, so that's your ceiling in a warm cabinet. For a 400 A distribution breaker feeding a downstream panel, that 36 kA gives you solid selectivity headroom against most transformer secondary faults. The Utilisation category is A, meaning it's not intended for frequent switching of motor loads — this is a distribution breaker, not a motor circuit protector.

Fixed mount on a backplate, front connection both top and bottom. IP20 finger-safe protection means it's suitable for enclosed distribution boards — no shock hazard during maintenance with the door open. IK07 impact resistance handles accidental tool drops during commissioning. Complies with EN/IEC 60947-2 and 60947-1, plus GB/T 14048.2 and JIS C8201-2-2 for Chinese and Japanese markets.

MPN
EZC400N3300