Schneider Electric EZC400N44400N

EZC400N44400N Schneider EasyPact EZC400N 400A 4P MCCB, 36kA

MPN EZC400N44400N
Obsolete

Schneider Electric EasyPact EZC400N series, EZC400N44400N, 4-pole molded-case circuit breaker, 400 A thermal-magnetic TM-D trip unit, 36 kA Icu at 440 V AC, fixed mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC400N44400N key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC400N44400N additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width140 mm
Height255 mm
Electrical life cyclesCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The 36 kA Icu at 440 V AC (IEC 60947-2) is the N-frame breaking capacity — enough for most distribution panels downstream of a transformer, but not for high-fault industrial mains. At 220/230 V it handles 40 kA Icu, so it's comfortable on 208Y/120 V or 240 V services too. The TM-D trip is a fixed thermal-magnetic curve — no interchangeable trip blocks, no electronic adjustment. The magnetic pickup is fixed at 4000 A (10× In), so it's a standard distribution curve, not a motor-protection or selective-coordination curve. For distribution feeders and general branch protection, that's fine. For motor circuits you'd want a Mag-Gard or electronic trip.

Where it goes — panel and deployment context

Fixed-mount, backplate-mounted breaker with front-front connections — line and load both terminate on the front face. The 45 mm pole pitch matches standard EasyPact busbar and accessory spacing. IK07 impact resistance handles incidental tool drops during maintenance. The toggle control and positive contact indication give a clear visual of breaker state — no ambiguity on whether it's tripped or off.

Standards and compliance — what the approvals mean

Listed to IEC 60947-2, EN 60947-2, GB/T 14048.2, and JIS C8201-2-2. The IEC 60947-2 standard covers low-voltage switchgear and controlgear for circuit breakers — it's the global benchmark for MCCB performance, thermal and magnetic calibration, and breaking capacity verification. The GB/T and JIS variants mean it's accepted in Chinese and Japanese markets without additional testing. No earth-leakage protection built in; if you need RCD functionality, you add a Vigicompact module or an external RCCB.

MPN
EZC400N44400N