Skip to main content
Schneider Electric EZCV250H3100

Schneider Electric EZCV250H3100 EasyPact EZCV250H MCCB, 100

MPN EZCV250H3100
Obsolete

Schneider Electric EasyPact EZCV250H, 3-pole MCCB, 100 A at 40 °C, 100 kA Icu at 240 V AC, thermal-magnetic TM-D trip with earth-leakage protection, IP20, backplate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZCV250H3100 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZCV250H3100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth68 mm
Width105 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZCV250H3100 is a 3-pole EasyPact EZCV250H moulded-case circuit breaker rated 100 A at 40 °C with a thermal-magnetic TM-D trip unit. Its breaking capacity reaches 100 kA Icu at 220–240 V AC, 36 kA at 380–415 V, and 25 kA at 440 V — all conforming to IEC 60947-2. That 100 kA figure at the common 240 V distribution level means it handles high fault currents typical of transformer-fed panels without cascading upstream, a key coordination advantage for the site electrical engineer. The breaker includes integral earth-leakage protection alongside overload and short-circuit functions, so it covers ground-fault detection in a single device — no separate RCCB needed downstream. The TM-D trip unit provides fixed thermal-magnetic curves suited for distribution and general-purpose loads. Category A utilisation (no intentional short-time delay) keeps it selective with upstream devices only when the upstream breaker is also Category A or the fault level stays within the instantaneous threshold. The breaker is certified for isolation (IEC 60947-2), meaning it can serve as a visible disconnect when locked off. Mechanical durability is 10,000 cycles, adequate for infrequent switching in a distribution board.

Mounting is fixed to a backplate. Connection pitch is 35 mm. Dimensions: 165 mm height, 105 mm width, 68 mm depth.

MPN
EZCV250H3100