Specifications

EZCV250H3100 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250H3100 — Mechanical
ParameterValue
Height165 mm
Width105 mm
Depth68 mm
EZCV250H3100 — Electrical
ParameterValue
[In] rated current100 A at 40 °C
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250H3100 — Specifications
ParameterValue
Poles description3P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250H
StandardsGB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2

Product details

The Schneider Electric EZCV250H3100 is a 3-pole EasyPact EZCV250H moulded-case circuit breaker rated 100 A at 40 °C with a thermal-magnetic TM-D trip unit. Its breaking capacity reaches 100 kA Icu at 220–240 V AC, 36 kA at 380–415 V, and 25 kA at 440 V — all conforming to IEC 60947-2. That 100 kA figure at the common 240 V distribution level means it handles high fault currents typical of transformer-fed panels without cascading upstream, a key coordination advantage for the site electrical engineer. The breaker includes integral earth-leakage protection alongside overload and short-circuit functions, so it covers ground-fault detection in a single device — no separate RCCB needed downstream. The TM-D trip unit provides fixed thermal-magnetic curves suited for distribution and general-purpose loads. Category A utilisation (no intentional short-time delay) keeps it selective with upstream devices only when the upstream breaker is also Category A or the fault level stays within the instantaneous threshold. The breaker is certified for isolation (IEC 60947-2), meaning it can serve as a visible disconnect when locked off. Mechanical durability is 10,000 cycles, adequate for infrequent switching in a distribution board.

Mounting is fixed to a backplate. Connection pitch is 35 mm. Dimensions: 165 mm height, 105 mm width, 68 mm depth.

Frequently asked questions

What is the closest pin-compatible alternative to EZCV250H3100 in this component family?

Within the EasyPac EZCV250H family, the closest alternative would be a variant with a different trip rating or breaking capacity code — for example, the EZCV250B3100 (B-code, lower Icu) or EZCV250N3100 (N-code, intermediate Icu). Pin-compatibility (same frame, same mounting footprint, same connection pitch) holds across the EZCV250H series, but the trip unit rating and breaking capacity must match the application's fault level. Verify the specific order code against your BOM before substituting.

What is EZCV250H3100's listed depth (68 mm) on this component line?

The depth is 68 mm. That is the front-to-back dimension of the breaker body, excluding the toggle handle projection.