Skip to main content
Schneider Electric EZCV250H3160

Schneider Electric EZCV250H3160 EasyPact MCCB, 160 A, 100 kA

MPN EZCV250H3160
Obsolete

Schneider Electric EasyPact EZCV250H series, EZCV250H3160, 3-pole molded case circuit breaker, 160 A at 40 °C, 100 kA Icu at 240 V AC, TM-D thermal-magnetic trip unit with earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZCV250H3160 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZCV250H3160 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth68 mm
Width105 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

MCCB for distribution duty with earth-leakage built in

The Schneider Electric EZCV250H3160 is a 3-pole molded case circuit breaker from the EasyPact EZCV250H series, rated 160 A at 40 °C and built for distribution applications. Its TM-D thermal-magnetic trip unit handles overload and short-circuit protection, and the unit includes integrated earth-leakage protection — so you get ground-fault detection without a separate add-on module. Breaking capacity hits 100 kA Icu at 220–240 V AC, 36 kA at 380–415 V, and 25 kA at 440 V, all per IEC 60947-2. That 100 kA figure at the common 240 V distribution level means it can sit upstream of a high-fault panel without cascading — useful for a main or feeder breaker in a commercial or light industrial board.

If your panel runs hotter, you derate; the TM-D unit is thermal-magnetic, so the thermal element responds to both current and ambient temperature. At 440 V the Icu drops to 25 kA, which still covers most 400 V distribution. The breaker is Category A (no intentional short-time delay), so it's a fast-acting device — coordination with downstream breakers relies on their instantaneous trip bands, not a delay curve.

Fixed mounting on a backplate — no DIN-rail adapter. IP20 finger-safe protection on the front, IK07 impact rating. Positive contact indication on the toggle gives visual confirmation of contact position — useful during commissioning and troubleshooting.

MPN
EZCV250H3160