Skip to main content
Schneider Electric EZCV250N3160

Schneider Electric EZCV250N3160 EasyPact MCCB, 160 A, 3P, 20

MPN EZCV250N3160
Obsolete

Schneider Electric EasyPact EZCV250N series, EZCV250N3160, molded case circuit breaker, 160 A, 3-pole, TM-D thermal-magnetic trip, 20 kA Icu at 440 V AC, with earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZCV250N3160 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZCV250N3160 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth68 mm
Width105 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZCV250N3160 is a 3-pole molded case circuit breaker from the EasyPact EZCV250N series, rated 160 A at 40 °C with a thermal-magnetic TM-D trip unit. It's built for distribution duty — overload, short-circuit, and earth-leakage protection in one package. The 20 kA Icu at 440 V AC (85 kA at 240 V, 25 kA at 415 V) tells you it can handle moderate fault levels on a 400 V line without cascading upstream.

The TM-D trip unit gives you fixed thermal (overload) and magnetic (short-circuit) settings; no adjustment dials, so the breaker is matched to the load at order time. Earth-leakage protection is built in, which saves an external RCCB or ground-fault module in panels where that's required. IP20 finger-safe terminals and IK07 impact resistance mean it's fine inside a locked enclosure but not for washdown zones.

Fixed backplate mount with front-front connections — both line and load terminals are accessible from the front, which simplifies busbar routing and panel wiring. Toggle control with positive contact indication gives a clear visual of the contact state. Mechanical durability of 10,000 cycles is typical for a distribution breaker — not for frequent switching duty, but fine for infrequent manual operation or remote shunt-trip use.

MPN
EZCV250N3160