Skip to main content
Schneider Electric EZCV250N3160 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZCV250N3160 EasyPact MCCB, 160 A, 3P, 20

MPNEZCV250N3160
Obsolete

Schneider Electric EasyPact EZCV250N series, EZCV250N3160, molded case circuit breaker, 160 A, 3-pole, TM-D thermal-magnetic trip, 20 kA Icu at 440 V AC, with earth-leakage protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZCV250N3160 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250N3160 — Mechanical
ParameterValue
Height165 mm
Width105 mm
Depth68 mm
EZCV250N3160 — Electrical
ParameterValue
[In] rated current160 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250N3160 — Specifications
ParameterValue
Poles description3P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250N
StandardsEN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2

Product details

The Schneider Electric EZCV250N3160 is a 3-pole molded case circuit breaker from the EasyPact EZCV250N series, rated 160 A at 40 °C with a thermal-magnetic TM-D trip unit. It's built for distribution duty — overload, short-circuit, and earth-leakage protection in one package. The 20 kA Icu at 440 V AC (85 kA at 240 V, 25 kA at 415 V) tells you it can handle moderate fault levels on a 400 V line without cascading upstream.

The TM-D trip unit gives you fixed thermal (overload) and magnetic (short-circuit) settings; no adjustment dials, so the breaker is matched to the load at order time. Earth-leakage protection is built in, which saves an external RCCB or ground-fault module in panels where that's required. IP20 finger-safe terminals and IK07 impact resistance mean it's fine inside a locked enclosure but not for washdown zones.

Fixed backplate mount with front-front connections — both line and load terminals are accessible from the front, which simplifies busbar routing and panel wiring. Toggle control with positive contact indication gives a clear visual of the contact state. Mechanical durability of 10,000 cycles is typical for a distribution breaker — not for frequent switching duty, but fine for infrequent manual operation or remote shunt-trip use.

Frequently asked questions

How do I get current pricing and availability for EZCV250N3160?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels.

What is the closest alternative to EZCV250N3160 in the EasyPact family?

The closest peer is the EZCV250N with a different trip rating or without earth-leakage protection. The EZCV250N3160 is distinguished by its 160 A TM-D trip and integrated earth-leakage module — if you don't need ground-fault protection, a standard EZCV250N without the 'E' suffix saves cost.

What compliance documentation does Schneider provide for EZCV250N3160?

The breaker is certified to EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It carries IP20 and IK07 ratings. Isolation suitability is confirmed per IEC 60947-2.

MPN
EZCV250N3160