Skip to main content
Schneider Electric EZS100E3016

Schneider Electric EZS100E3016 EasyPact EZS MCB, 16 A, 3P, 5

MPN EZS100E3016
Obsolete

Schneider Electric EasyPact EZS, EZS100E3016, thermal-magnetic circuit breaker, 16 A, 3P, 50 kA Icu at 240 V AC, TM-D trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZS100E3016 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2
Insulation voltage ui690 V conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 17 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 200/230 V AC 50/60 Hz conforming to GB 14048.2 25 kA Icu at 380/400 V AC 50/60 Hz conforming to GB 14048.2
IP ratingIP40
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

EZS100E3016 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth60 mm
Width75 mm
Height130 mm
Electrical life cycles4000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2
Mechanical life cycles13000 cycles conforming to EN/IEC 60947-2 20000 cycles conforming to GB 14048.2
Operating temperature-35...70 °C

Product details

The breaking capacity reaches 50 kA Icu at 220/240 V AC and 25 kA Icu at 380/400 V AC — figures that govern its use in high-fault-current panelboards where upstream coordination matters.

The TM-D trip unit has a fixed thermal pickup at 1× In and a magnetic instantaneous threshold at 300 kA (integral instant protection), meaning magnetic trips only on very high faults, not on motor inrush. The 50 kA Icu at 240 V AC is the maximum short-circuit current the breaker can interrupt once and remain functional; at 415 V it drops to 25 kA, and at 440 V to 17 kA.

Fixed backplate mounting, front connections both top and bottom. Pollution degree 3 (IEC 60947-1) means it tolerates conductive pollution in industrial enclosures — no special sealing needed inside a standard IP40 panel. The IP40 housing keeps out tools and fingers but not water; mount it in a dry cabinet or add an outer enclosure for washdown areas.

MPN
EZS100E3016