Skip to main content
Schneider Electric EZS630N3500

Schneider Electric EZS630N3500 EasyPact EZS Circuit Breaker,

MPN EZS630N3500
Obsolete

Schneider Electric EasyPact EZS, circuit breaker, 3P, 500 A at 40 °C, TM-D thermal-magnetic trip unit, 70 kA Icu at 240 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZS630N3500 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2
Insulation voltage ui690 V conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220/230 V AC 50/60 Hz conforming to GB 14048.2 50 kA Icu at 440 V AC 50/60 Hz conforming to GB 14048.2
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

EZS630N3500 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth110 mm
Width182 mm
Height257 mm
Electrical life cycles8000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2
Mechanical life cycles15000 cycles conforming to EN/IEC 60947-2 10000 cycles conforming to GB 14048.2
Operating temperature-35...70 °C

Product details

At 400 V AC the breaking capacity is still 50 kA Icu, which covers most North American 480Y/277 V and European 400 V distribution panels. The TM-D trip unit provides fixed long-time pickup at 1 In (500 A) and a fixed magnetic instantaneous trip threshold, so there is no field-adjustable thermal or magnetic dial. That simplifies ordering — you get one setting — but means the breaker is not a candidate for systems needing coordination curve tuning. The 5000 kA integral instant protection rating is the maximum prospective short-circuit current the trip element can withstand, not the system SCCR; the system SCCR is governed by the Icu values at the actual system voltage.

Deployment context

Fixed backplate mounting with front-front connections (line and load both front-facing). The 45 mm pole pitch matches standard busbar and cable lug spacing for 500 A class breakers.

MPN
EZS630N3500