Skip to main content
Schneider Electric GV4L07N6

Schneider Electric GV4L07N6 TeSys GV4 Motor Circuit Breaker,

MPN GV4L07N6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4L07N6, 3-pole, 7 A rated current, 100 kA breaking capacity at 240 V AC, magnetic-electronic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4L07N6 key specifications
ParameterValue
Control typeRotary handle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4L07N6 additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth165 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

Motor power coverage and trip characteristics

The GV4L07N6: This 7 A frame covers a wide motor power band depending on line voltage: 1.5 kW at 400 V, up to 4 kW at 500 V, and as high as 7.5 kW at 690 V. The magnetic trip threshold is adjustable between 42 and 98 A — that is the short-circuit / instantaneous trip, not the overload. The electronic overload element handles the thermal curve. The utilisation category is AC-3 (squirrel-cage motor starting) per IEC 60947-4-1, which is the standard for direct-on-line motor starting.

Durability and environmental ratings for continuous duty

Rated for continuous duty per IEC 60947-4-1. Electrical durability is 40,000 cycles at AC-3 at 440 V, both at In and at In/2 — that is the number of motor starts before the contacts need replacement. Mechanical durability matches at 40,000 cycles. The maximum operating rate is 25 cycles per hour, so it is sized for a machine that starts a motor every couple of minutes, not a high-speed jogging application. The enclosure is IP40 (finger-safe, no water ingress protection) and IK07 (impact resistance up to 2 J).

Integration into the panel: dimensions, connections, and isolation

Dimensions are 155 mm high, 81 mm wide, and 165 mm deep. The connection pitch is 27 mm without spreaders, 35 mm with spreaders — this matters when laying out multiple breakers on a DIN rail for busbar connection. Terminals accept lugs or ring terminals; tightening torque is 9 N·m for the main power cables (16–95 mm²) and 5 N·m for control wiring (1.5–10 mm²). Operating position is any, and the altitude rating goes to 5000 m, so it works in high-altitude installations without derating.

MPN