Skip to main content
Schneider Electric GV4L80N6

Schneider GV4L80N6 TeSys GV4 Motor Circuit Breaker, 80 A

MPN GV4L80N6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4L80N6, 80 A, 3-pole, 37 kW at 400 V, 100 kA breaking capacity.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4L80N6 key specifications
ParameterValue
Control typeRotary handle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4L80N6 additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth165 mm
Width81 mm
Height155 mm
Electrical life cycles14000 cycles for AC-3 at 440 V In/2 7000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

It combines magnetic and electronic trip technology for overload and short-circuit protection of motors up to 37 kW at 400 V AC. Rated for AC-3 utilisation category per IEC 60947-4-1, meaning it's built to switch motor loads under full load and handle the inrush without nuisance tripping. The 80 A In covers a solid range of medium-horsepower motors — think conveyors, pumps, compressors in a 400 V panel. Breaking capacity hits 100 kA Icu at 240 V AC per IEC 60947-2, dropping to 50 kA at 400 V and 8 kA at 690 V. That 50 kA at 400 V gives real headroom for high-fault installations; you can coordinate this downstream of a larger feeder without worrying about cascading failure.

The TeSys GV4 family is the successor to the older GV2 and GV3 ranges, offering higher breaking capacities and electronic trip adjustability. If you're migrating from a GV2ME or GV3P, the GV4L80N6 is the direct replacement — same DIN-rail footprint, same rotary-handle interface.

Mounts on DIN rail, three-pole format, 81 mm wide by 155 mm tall by 165 mm deep. That 165 mm depth is the key dimension for shallow enclosures — verify gland plate clearance before routing cables. Terminals accept lug-ring connections: 9 N·m torque for 16–95 mm² cable, 5 N·m for 1.5–10 mm². The 27 mm connection pitch (35 mm with spreaders) matches standard busbar systems. IP40 front face, IK07 impact rating — fine for general industrial panels, not for washdown zones. Operating altitude up to 5000 m without derating.

Performance and durability

Mechanical durability rated at 40,000 cycles, electrical durability at 14,000 cycles for AC-3 at 440 V at half rated current, 7,000 at full rated current. That's a solid lifespan for a motor starter — plan for replacement around 7,000 full-load operations if the motor starts frequently. Continuous duty rated per IEC 60947-4-1 — no derating needed for sustained motor running. Magnetic tripping current range 480–1120 A, adjustable via the electronic trip unit. That gives flexibility to set the short-circuit pickup based on motor inrush characteristics. Power dissipation 6.1 W per pole — total 18.3 W at full load, worth factoring into enclosure thermal calculations.

MPN
GV4L80N6