Skip to main content
Schneider Electric GV4LE03N

GV4LE03N TeSys GV4 Motor Circuit Breaker, 3.5 A, 3P

MPN GV4LE03N
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4LE03N, 3-pole, 3.5 A rated current, magnetic-electronic trip, 100 kA breaking capacity at 240 V.

$391.17 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE03N key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4LE03N additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The GV4LE03N is a 3-pole motor circuit breaker from the Schneider Electric TeSys GV4 range, rated at 3.5 A continuous current for motor protection.

The 3.5 A In sets the continuous current the breaker will carry without tripping — match this to the motor full-load current. The magnetic trip range of 21...49 A provides instantaneous short-circuit protection; the electronic overload handles the thermal curve. Motor power ratings span 0.55 kW at 400 V up to 2.2 kW at 690 V, so one breaker covers a range of motor sizes depending on line voltage. The utilisation category AC-3 confirms it is rated for switching squirrel-cage motors — starting and stopping under load. Suitability for isolation per IEC 60947-1 means this breaker can serve as a visible-disconnect point — no separate isolator needed upstream.

The GV4LE03N occupies a 81 x 155 x 116 mm footprint on the DIN rail. EverLink BTR screw terminals accept up to 95 mm² on the bottom (load side) and 70 mm² on the top (line side), with tightening torques of 9 N·m for larger cables and 5 N·m for smaller ones. IK07 impact rating handles incidental tool drops during commissioning. Maximum operating rate is 25 cycles per hour — enough for manual start/stop but not for high-speed jogging. Mechanical durability is 40,000 cycles; electrical durability is also 40,000 cycles at AC-3 rated current.

MPN
GV4LE03N