Skip to main content
Schneider Electric GV4LE03N — Motor Protection Circuit Breakers (MPCB)

GV4LE03N TeSys GV4 Motor Circuit Breaker, 3.5 A, 3P

MPNGV4LE03N
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4LE03N, 3-pole, 3.5 A rated current, magnetic-electronic trip, 100 kA breaking capacity at 240 V.

$391.17Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV4LE03N — Mechanical
ParameterValue
Height155 mm
Width81 mm
Depth116 mm

Product details

The GV4LE03N is a 3-pole motor circuit breaker from the Schneider Electric TeSys GV4 range, rated at 3.5 A continuous current for motor protection.

The 3.5 A In sets the continuous current the breaker will carry without tripping — match this to the motor full-load current. The magnetic trip range of 21...49 A provides instantaneous short-circuit protection; the electronic overload handles the thermal curve. Motor power ratings span 0.55 kW at 400 V up to 2.2 kW at 690 V, so one breaker covers a range of motor sizes depending on line voltage. The utilisation category AC-3 confirms it is rated for switching squirrel-cage motors — starting and stopping under load. Suitability for isolation per IEC 60947-1 means this breaker can serve as a visible-disconnect point — no separate isolator needed upstream.

The GV4LE03N occupies a 81 x 155 x 116 mm footprint on the DIN rail. EverLink BTR screw terminals accept up to 95 mm² on the bottom (load side) and 70 mm² on the top (line side), with tightening torques of 9 N·m for larger cables and 5 N·m for smaller ones. IK07 impact rating handles incidental tool drops during commissioning. Maximum operating rate is 25 cycles per hour — enough for manual start/stop but not for high-speed jogging. Mechanical durability is 40,000 cycles; electrical durability is also 40,000 cycles at AC-3 rated current.

Frequently asked questions

What is the breaking capacity of the GV4LE03N?

Breaking capacity is 100 kA Icu at 220...240 V AC, 50 kA at 380...415 V AC, 50 kA at 440 V AC, 25 kA at 500 V AC, 15 kA at 525 V AC, and 8 kA at 660...690 V AC, all per IEC 60947-2.

What motor power range does the GV4LE03N cover?

It covers 0.55 kW at 400...415 V up to 2.2 kW at 660...690 V AC, depending on supply voltage. Specific ratings: 0.55 kW at 400 V, 0.75 kW at 500 V, 1.1 kW at 690 V, and 2.2 kW at 690 V.

What compliance standards does the GV4LE03N meet?

It is certified to EN/IEC 60947-4-1 (motor starter) and EN/IEC 60947-2 (circuit breaker). It also meets IACS for climatic withstand and IEC 60068-2-6/27 for vibration and shock.

MPN
GV4LE03N