Schneider GV4LE07S TeSys Deca Motor Circuit Breaker, 7 A, 12

MPN GV4LE07S
Active

Schneider Electric TeSys Deca GV4L, GV4LE07S, 3-pole motor circuit breaker, 7 A In, 120 kA Icu at 240 V AC, 100 kA at 415 V AC.

$416.21 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE07S key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3

All specifications

GV4LE07S additional specifications
ParameterValue
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

What It Is and the Rating That Decides Fit

The Schneider Electric GV4LE07S is a 3-pole motor circuit breaker from the TeSys Deca range, rated 7 A continuous current (In) and built for motor protection duty under EN/IEC 60947-4-1 and EN/IEC 60947-2. The headline number is the 7 A In — that is the continuous current the thermal-magnetic trip allows before overload protection acts. For a 400 V three-phase supply, this breaker covers motor outputs from 1.5 kW up to 3 kW depending on the exact line voltage, and up to 7.5 kW at 690 V. The magnetic trip is set at 42...98 A, so it handles the inrush of a motor up to about 14x FLC without nuisance tripping.

Breaking Capacity — What It Means for Coordination

The short-circuit breaking capacity (Icu) is 120 kA at 240 V AC, 100 kA at 415 V, and still 10 kA at 690 V. The Utilisation Category A (IEC 60947-2) confirms it is not intended for selectivity under fault; if you need full discrimination, pair it with a TeSys GV7 or a fuse-switch upstream.

Panel fit: 81 mm wide, 155 mm high, 116 mm deep. Screw terminals on top accept 1.5...70 mm² solid or 1.5...50 mm² flexible; bottom terminals accept up to 95 mm² solid. Tightening torque is 9 N·m for the larger cable range.

MPN