Skip to main content
Schneider Electric GV4LE07S — Motor Protection Circuit Breakers (MPCB)

Schneider GV4LE07S TeSys Deca Motor Circuit Breaker, 7 A, 12

MPNGV4LE07S
Active

Schneider Electric TeSys Deca GV4L, GV4LE07S, 3-pole motor circuit breaker, 7 A In, 120 kA Icu at 240 V AC, 100 kA at 415 V AC.

$416.21Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV4LE07S — Mechanical
ParameterValue
Height155 mm
Width81 mm
Depth116 mm

Product details

What It Is and the Rating That Decides Fit

The Schneider Electric GV4LE07S is a 3-pole motor circuit breaker from the TeSys Deca range, rated 7 A continuous current (In) and built for motor protection duty under EN/IEC 60947-4-1 and EN/IEC 60947-2. The headline number is the 7 A In — that is the continuous current the thermal-magnetic trip allows before overload protection acts. For a 400 V three-phase supply, this breaker covers motor outputs from 1.5 kW up to 3 kW depending on the exact line voltage, and up to 7.5 kW at 690 V. The magnetic trip is set at 42...98 A, so it handles the inrush of a motor up to about 14x FLC without nuisance tripping.

Breaking Capacity — What It Means for Coordination

The short-circuit breaking capacity (Icu) is 120 kA at 240 V AC, 100 kA at 415 V, and still 10 kA at 690 V. The Utilisation Category A (IEC 60947-2) confirms it is not intended for selectivity under fault; if you need full discrimination, pair it with a TeSys GV7 or a fuse-switch upstream.

Panel fit: 81 mm wide, 155 mm high, 116 mm deep. Screw terminals on top accept 1.5...70 mm² solid or 1.5...50 mm² flexible; bottom terminals accept up to 95 mm² solid. Tightening torque is 9 N·m for the larger cable range.

Frequently asked questions

What is the closest alternative to the GV4LE07S in the TeSys Deca family?

Within the TeSys Deca GV4L range, the closest sibling is the GV4LE07S itself — there is no direct pin-compatible alternative at the same 7 A rating. For a different current rating, the GV4L range offers models from 0.4 A up to 80 A, but each has a unique thermal-magnetic trip setting. No pin-compatible drop-in exists; the entire breaker must be swapped if the current rating changes.

What is the depth of the GV4LE07S?

The GV4LE07S has a depth of 116 mm. Overall dimensions are 81 mm width, 155 mm height, and 116 mm depth.

What is the range of the GV4LE07S?

The GV4LE07S belongs to the TeSys Deca range (product name TeSys GV4). It is a motor circuit breaker designed for motor protection.

What compliance documentation does the GV4LE07S have?

The GV4LE07S is certified to EN/IEC 60947-4-1 and EN/IEC 60947-2. It has a fire resistance rating of 960 °C per IEC 60695-2-11, climatic withstand per IACS, and vibration/shock robustness per IEC 60068-2-6 and IEC 60068-2-27. It is suitable for isolation per IEC 60947-1.

MPN
GV4LE07S