Schneider Electric GV4LE07S6

Schneider TeSys GV4LE07S6 Motor Circuit Breaker, 7 A, 3P

MPN GV4LE07S6
Active

Schneider Electric TeSys GV4, motor circuit breaker, 3P, 7 A rated current, magnetic-electronic trip, 120 kA breaking capacity at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE07S6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4LE07S6 additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

It combines magnetic and electronic trip technology to protect motor circuits against short-circuits and overloads, with a magnetic tripping window of 42...98 A. Rated for AC-3 duty per IEC 60947-4-1, it handles the high inrush of squirrel-cage motors during starting and the lower running current under load. The 7 A frame covers motor outputs from 1.5 kW up to 7.5 kW depending on supply voltage (400 V to 690 V AC). Breaking capacity reaches 120 kA Icu at 240 V AC and 100 kA at 415 V AC per IEC 60947-2, meaning it can safely interrupt a fault current up to that level without welding contacts or cascading damage upstream. This is a strong SCCR for a 7 A frame — suitable for high-fault installations.

The GV4L footprint is 81 mm wide, 155 mm high, and 116 mm deep — a compact 3-pole block that mounts on a DIN rail or panel. Connection pitch is 27 mm without spreaders, widening to 35 mm with spreaders for larger cable lugs. Terminal tightening torque is 9 N·m for the main power cables (16...95 mm²) and 5 N·m for control wiring (1.5...10 mm²). IP40 front protection and IK07 impact resistance suit it for enclosed panel installation where occasional tool drops or debris are a risk.

For motor protection, you size this to match the motor's full-load current, not the nameplate kW. The magnetic trip setting of 42...98 A is fixed and non-adjustable — it must fall above the motor's starting inrush to avoid nuisance trips. Electrical durability is 40,000 cycles at AC-3 duty at 440 V — a solid service life for a motor-starter application. Mechanical durability matches at 40,000 cycles. Maximum operating rate is 25 cycles per hour, so it is not intended for high-speed jogging or rapid cycling. Power dissipation per pole is 6.1 W, totaling about 18.3 W for the three poles at full rated current. This matters for thermal management inside a sealed enclosure — check the cabinet's temperature rise if multiple breakers are ganged together.