Schneider Electric GV4LE12S6

Schneider TeSys GV4LE12S6 Motor Circuit Breaker, 12.5 A, 3 k

MPN GV4LE12S6
Obsolete

Schneider Electric TeSys GV4 motor circuit breaker, GV4LE12S6, 3-pole, 12.5 A rated current, magnetic-electronic trip, 3 kW at 400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE12S6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4LE12S6 additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The GV4LE12S6 is a 3-pole motor circuit breaker from the TeSys GV4 series, rated 12.5 A continuous. That 12.5 A is the thermal setting — it protects the motor feeder, not the motor itself, so pair it with a separate overload relay downstream. The magnetic trip range of 75…175 A handles inrush without nuisance tripping on DOL starts. Breaking capacity hits 120 kA Icu at 240 V AC and 100 kA at 415 V AC per IEC 60947-2. Rated for motor duty in AC-3 utilisation category per IEC 60947-4-1, so it switches 3 kW at 400 V and up to 11 kW at 690 V. The electrical durability is 40,000 cycles at full AC-3 load — that's the mechanical life too, so it's matched for frequent switching applications like conveyor or pump cycling.

The IP40 front panel protection means it's fine inside a standard enclosure but not for washdown areas. Operating altitude goes to 5000 m, so it works in high-altitude installations without derating. Terminals accept lugs or ring terminals — torque to 9 N·m for cables 16…95 mm² on the line/load side, and 5 N·m for 1.5…10 mm² on the control wiring. The toggle control gives a clear visual indication of the contact position for isolation duty (it's marked suitable for isolation per IEC 60947-1).

MPN
GV4LE12S6