Skip to main content
Schneider Electric GV4LE12S6 — Motor Protection Circuit Breakers (MPCB)

Schneider TeSys GV4LE12S6 Motor Circuit Breaker, 12.5 A, 3 k

MPNGV4LE12S6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4LE12S6, 3-pole, 12.5 A rated current, magnetic-electronic trip, 3 kW at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV4LE12S6 — Mechanical
ParameterValue
Height155 mm
Width81 mm
Depth116 mm

Product details

The GV4LE12S6 is a 3-pole motor circuit breaker from the TeSys GV4 series, rated 12.5 A continuous. That 12.5 A is the thermal setting — it protects the motor feeder, not the motor itself, so pair it with a separate overload relay downstream. The magnetic trip range of 75…175 A handles inrush without nuisance tripping on DOL starts. Breaking capacity hits 120 kA Icu at 240 V AC and 100 kA at 415 V AC per IEC 60947-2. Rated for motor duty in AC-3 utilisation category per IEC 60947-4-1, so it switches 3 kW at 400 V and up to 11 kW at 690 V. The electrical durability is 40,000 cycles at full AC-3 load — that's the mechanical life too, so it's matched for frequent switching applications like conveyor or pump cycling.

The IP40 front panel protection means it's fine inside a standard enclosure but not for washdown areas. Operating altitude goes to 5000 m, so it works in high-altitude installations without derating. Terminals accept lugs or ring terminals — torque to 9 N·m for cables 16…95 mm² on the line/load side, and 5 N·m for 1.5…10 mm² on the control wiring. The toggle control gives a clear visual indication of the contact position for isolation duty (it's marked suitable for isolation per IEC 60947-1).

Frequently asked questions

What are the key ratings for this motor circuit breaker?

Rated current 12.5 A, breaking capacity 120 kA at 240 V AC, motor power 3 kW at 400 V AC, magnetic trip range 75…175 A, and rated operational voltage 690 V AC.

What standards does the GV4LE12S6 comply with?

It complies with EN/IEC 60947-2 for circuit-breaker performance and EN/IEC 60947-4-1 for motor-starter coordination. It is also suitable for isolation per IEC 60947-1.

What is the closest alternative in the TeSys family?

Within the TeSys GV4 series, the GV4LE12S6 is the 12.5 A variant. The GV4LE16S6 is the next step up at 16 A, sharing the same frame size, connection pitch, and breaking capacity ratings. The choice between them is purely the continuous current setting needed for the motor feeder.

MPN
GV4LE12S6