Skip to main content
Schneider Electric GV4PEM115B6

Schneider Electric GV4PEM115B6 TeSys GV4 MPCB, 115 A, 3-Pole

MPN GV4PEM115B6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM115B6, 3-pole, 115 A line rated, thermal-magnetic and electronic trip, 50 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4PEM115B6 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz IEC 60947-2
Breaking capacity50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947
Utilization categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IP ratingIP40
Terminal pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

GV4PEM115B6 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-58...185 °F (-50...85 °C)
Pollution degree3
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical life cycles10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-13...158 °F (-25...70 °C)

Product details

115 A motor circuit breaker for TeSys Deca panels

The GV4PEM115B6: It combines thermal-magnetic and electronic trip technology to protect motors against overload, short-circuit, and phase failure — the electronic element provides adjustable protection curves that a purely thermal device cannot. At 415 V the rating drops to 25 kA, still adequate for typical motor branch circuits.

Motor power coverage and trip coordination

This breaker covers motors from 37 kW up to 110 kW depending on supply voltage — for example, 37 kW at 400 V, 55 kW at 500 V, and 110 kW at 690 V. The wide power range means a single frame size handles multiple motor ratings, simplifying panel stock. Magnetic trip threshold is fixed at 1955 A, which is 17× the line rating — this prevents nuisance tripping on motor inrush while still clearing a bolted fault quickly. Phase failure sensitivity per IEC 60947-4-1 ensures the breaker opens if one phase drops out, avoiding single-phase motor burnup. Mechanical durability is 40,000 cycles.

Dimensions are 6.1 in (155 mm) high, 3.2 in (81 mm) wide, and 4.6 in (116 mm) deep — fits standard 35 mm DIN rail. Connection pitch is 27 mm without spreaders, expanding to 35 mm with spreaders for larger cable lugs up to 95 mm². IP40 front protection and IK07 impact resistance suit indoor panel environments. Pollution degree 3 means it tolerates conductive dust and occasional condensation — typical for factory-floor enclosures without climate control.

The fire resistance rating of 960 °C per IEC 60695-2-11 supports global panel certification requirements.

MPN
GV4PEM115B6