Skip to main content
Schneider Electric GV4PEM50B6

Schneider GV4PEM50B6 TeSys Deca MPCB, 50 A, 50 kA

MPN GV4PEM50B6
Active

Schneider Electric TeSys Deca GV4PEM50B6 motor circuit breaker, 3-pole, 50 A rated current, thermal-magnetic and electronic trip, 50 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4PEM50B6 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz IEC 60947-2
Breaking capacity50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947
Utilization categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IP ratingIP40
Terminal pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

GV4PEM50B6 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-58...185 °F (-50...85 °C)
Pollution degree3
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical life cycles20000 cycles AC-3 440 V In/2 10000 cycles AC-3 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-13...158 °F (-25...70 °C)

Product details

50 A motor circuit breaker with 50 kA interrupting capacity

The GV4PEM50B6: Rated for AC-3 utilisation category per IEC 60947-4-1, this MPCB is designed specifically for switching motor loads — not just resistive heating.

Dual trip technology and phase loss protection

The trip unit combines thermal-magnetic and electronic elements — the thermal bimetal handles overloads with an inverse-time curve, while the magnetic coil (850 A fixed) clears short-circuits. The electronic circuit adds phase-failure sensitivity per IEC 60947-4-1, so a lost phase on the line side trips the breaker before single-phasing damages the motor. Power dissipation is 4.6 W per pole at rated current — budget this into the panel thermal calculation when grouping multiple MPCBs in a closed enclosure. The 40,000-cycle mechanical endurance and 20,000-cycle electrical endurance at AC-3 rated current give a realistic service life for production machinery running 25 cycles per hour maximum operating rate.

Panel fit and compliance documentation

The GV4PEM50B6 mounts on standard DIN rail with a 27 mm connection pitch between poles — this matches the TeSys Deca busbar system without spreaders. With spreaders fitted, the pitch opens to 35 mm to accommodate larger cable lugs up to 95 mm². The IP40 front face and IK07 impact resistance are adequate for enclosed panel mounting; this is not a washdown-rated device.