Skip to main content
Schneider Electric GV4PEM80S

Schneider Electric GV4PEM80S TeSys GV4 Motor Circuit Breaker

MPN GV4PEM80S
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM80S, 80 A, 3-pole, thermal-magnetic with electronic trip, 120 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.

$1,072.45 – $1,420.11 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4PEM80S key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz IEC 60947-2
Breaking capacity120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA 208Y/120 V AC 50/60 Hz UL 60947 100 kA 240 V AC 50/60 Hz UL 60947 65 kA 480Y/277 V AC 50/60 Hz UL 60947 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA 600Y/347 V AC 50/60 Hz UL 60947
Utilization categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4PEM80S additional specifications
ParameterValue
Storage temperature-58...185 °F (-50...85 °C)
Pollution degree3
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical life cycles14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-13...158 °F (-25...70 °C)

Product details

80 A motor circuit breaker for 37 kW at 400 V

The GV4PEM80S: It combines motor protection and isolation in one DIN-rail-mounted device, replacing a separate breaker and contactor in many panel layouts. At 480Y/277 V UL rating drops to 65 kA, still covering most industrial service entrances.

Trip unit and motor protection logic

Dual-technology trip: thermal-magnetic for overload and short-circuit, plus an electronic module for phase-failure sensitivity per IEC 60947-4-1. Magnetic trip threshold is fixed at 1360 A — 17× In — meaning it clears bolted faults fast but won't nuisance-trip on motor inrush. Rated for continuous duty (IEC 60947-4-1) and utilisation category AC-3, so it's built for starting and stopping squirrel-cage motors under load. Electrical durability is 14,000 cycles at AC-3 440 V at In/2, and 7,000 cycles at full In — plan spares for high-cycle applications. Mechanical life is 40,000 cycles, with a max operating rate of 25 cycles/hour. The toggle control gives positive manual on/off and trip indication — no auxiliary power needed for the isolation function.

Footprint is 81 mm wide × 155 mm high × 116 mm deep — fits a standard 3-module DIN-rail slot. IP40 enclosure with IK07 impact resistance; fine for inside a panel but not for washdown zones. EverLink BTR screw terminals on top accept 1.5...70 mm² solid or 1.5...50 mm² flexible; bottom terminals take 2.5...95 mm² solid or 2.5...70 mm² flexible. Tightening torque is 9 N·m for the main power terminals, 5 N·m for the control wiring — use a torque screwdriver; the EverLink clamp is sensitive to over-torque. Power dissipation is 4.6 W per pole — 13.8 W total at rated current. Factor this into the panel thermal budget; in a sealed enclosure with multiple breakers, the heat adds up.

Suitable for isolation per IEC 60947-1 — no need for a separate disconnect. Sourced to order against BOM quantities through independent distribution.

MPN
GV4PEM80S