Skip to main content
Schneider Electric LADN04A

LADN04A TeSys Deca Auxiliary Contact Block, 4NC, 690V, 10A

MPN LADN04A
Active

Schneider Electric TeSys Deca auxiliary contact block, LADN04A, 4NC, front mounting, snap-in terminals, 10 A thermal, 690 V insulation.

$54.06 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LADN04A specifications
ParameterValue
Protection typeGG fuse 10 A
Main product or component typeAuxiliary contact block
Voltage690 V AC 25...400 Hz
Insulation voltage ui690 V IEC 60947-5-1
Current6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
IP ratingIP20
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-76...176 °F (-60...80 °C)
ColorDark grey
Depth1.7 in (42 mm)
Width1.7 in (44 mm)
Height1.9 in (48 mm)
Mechanical life cycles30 Mcycles
Operating temperature23...140 °F (-5...60 °C)

Product details

The LADN04A is a TeSys Deca auxiliary contact block — four normally-closed instantaneous contacts that mount to the front of a contactor or reversing starter in the same series. The operational current depends on duty: 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13 — so for a 24 VDC PLC input circuit the DC-13 rating at 125 V is the relevant curve, not the AC figure.

Minimum switching capability is 5 mA at 17 V — below that, the contact film may not break reliably. For dry-circuit logic (e.g. 5 V / 1 mA PLC inputs), pair this block with a gold-plated contact block or use a solid-state interface. Mechanical durability is 30 million cycles — typical for a contactor-mounted auxiliary block in high-cycle packaging or conveyor applications. The short-time withstand ratings (100 A for 1 s, 140 A for 100 ms) cover inrush from contactor coils or small solenoids switched through the block.

Compliant with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, and GB/T 14048.5. Also listed for glow-wire testing per IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ — relevant for appliance and HVAC panel builds where the contactor block is in the flame path.

MPN
LADN04A