Skip to main content
Schneider Electric LADN04A — Motor Control Accessories

LADN04A TeSys Deca Auxiliary Contact Block, 4NC, 690V, 10A

MPNLADN04A
Active

Schneider Electric TeSys Deca auxiliary contact block, LADN04A, 4NC, front mounting, snap-in terminals, 10 A thermal, 690 V insulation.

$54.06Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LADN04A — Identification
ParameterValue
Product / component typeAuxiliary contact block
Product rangeTeSys TeSys Deca
LADN04A — Electrical
ParameterValue
Rated operational voltage (Ue)690 V AC 25...400 Hz
Pole / contact composition4 NC
LADN04A — Cable & Connector
ParameterValue
Terminal connection capacitysnap-in terminal 1 0.002...0.006 in² (1...4 mm²)flexible with cable end snap-in terminal 1 0.002...0.006 in² (1...4 mm²)flexible without cable end snap-in terminal 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end snap-in terminal 2 0.002...0.006 in² (1...4 mm²)flexible without cable end snap-in terminal 1 0.002...0.006 in² (1...4 mm²)rigid without cable end snap-in terminal 2 0.002...0.006 in² (1...4 mm²)rigid without cable end
LADN04A — Mechanical
ParameterValue
Width1.7 in (44 mm)
Height1.9 in (48 mm)
Depth1.7 in (42 mm)
LADN04A — Environmental
ParameterValue
IP protection ratingIP20 conforming to IEC 60529
Operating ambient temperature23...140 °F (-5...60 °C)
Storage ambient temperature-76...176 °F (-60...80 °C)
Operating altitude9842.52 ft (3000 m)
Environmental classNormal environment
LADN04A — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ

Product details

The LADN04A is a TeSys Deca auxiliary contact block — four normally-closed instantaneous contacts that mount to the front of a contactor or reversing starter in the same series. The operational current depends on duty: 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13 — so for a 24 VDC PLC input circuit the DC-13 rating at 125 V is the relevant curve, not the AC figure.

Minimum switching capability is 5 mA at 17 V — below that, the contact film may not break reliably. For dry-circuit logic (e.g. 5 V / 1 mA PLC inputs), pair this block with a gold-plated contact block or use a solid-state interface. Mechanical durability is 30 million cycles — typical for a contactor-mounted auxiliary block in high-cycle packaging or conveyor applications. The short-time withstand ratings (100 A for 1 s, 140 A for 100 ms) cover inrush from contactor coils or small solenoids switched through the block.

Compliant with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, and GB/T 14048.5. Also listed for glow-wire testing per IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ — relevant for appliance and HVAC panel builds where the contactor block is in the flame path.

Frequently asked questions

What is the closest alternative to LADN04A in the TeSys Deca family?

The LADN04 is the 4NC front-mount block with screw-clamp terminals; the LADN04A uses snap-in terminals. If your panel wiring is already screw-clamp, the LADN04 is functionally identical — same contact configuration, same ratings. For a mixed NC/NO configuration, the LADN11 (1NO+1NC) or LADN22 (2NO+2NC) are the obvious choices.

What compliance documentation is available for LADN04A?

The block carries UL, CSA, and CE marks per the listed standards (UL 60947-5-1, CSA C22.2 No 60947-5-1, EN/IEC 60947-5-1). RoHS and REACH declarations are standard for Schneider TeSys product lines; request the declaration of conformity with your RFQ.

MPN
LADN04A