Skip to main content
Schneider Electric LADR09

TeSys Deca LADR09 Off-Delay Timer Block, 0.3-3s, 1NO+1NC

MPN LADR09
Obsolete

Schneider Electric TeSys Deca LADR09, off-delay time delay auxiliary contact block, 1NO+1NC, 0.3-3 s range, front mount, Faston terminals, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LADR09 specifications
ParameterValue
Timer typeOff delay
Protection typeGG fuse 10 A
Voltage690 V AC 25...400 Hz
Insulation voltage ui690 V IEC 60947-5-1 600 V UL 60947-5-1 600 V CSA C22.2 No 60947-5-1
Current6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
IP ratingIP20
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max70 °C
Temp operating min-40 °C
Storage temperature-76...176 °F (-60...80 °C)
Depth2.4 in (61 mm)
Width1.7 in (44 mm)
Height1.9 in (48 mm)
Mechanical life cycles5 Mcycles
Time delay range0.3–3 s
Operating temperature-40...158 °F (-40...70 °C)

Product details

Product Description and Key Ratings

The LADR09 is an off-delay time delay auxiliary contact block from the TeSys Deca range, configured as 1 normally open plus 1 normally closed contact. The time delay range is 0.3 to 3 seconds, set via an external adjustment on the front face. It mounts on the front of a TeSys Deca contactor or reversing starter, occupying the auxiliary slot, and connects via Faston terminals rated for 10 A conventional free air thermal current at 60 °C. Rated operational current per IEC 60947-5-1: 6 A at 120 V AC-15 (pilot duty), 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. Minimum switching capability is 5 mA at 17 V, which means it can reliably switch low-level PLC inputs and signal-level loads without contact wetting issues. The block carries an IP20 degree of protection per IEC 60529, suitable for installation inside a closed control panel. Mechanical durability is rated at 5 million cycles.

Integration Notes

The block mounts on the front of a TeSys Deca contactor or reversing starter, occupying the auxiliary contact slot. Faston terminals (0.25 in / 6.35 mm) accept standard spade connectors; strip length and crimp tool selection follow the manufacturer's wiring recommendations for 0.75 to 2.5 mm² stranded wire. The off-delay function starts when the contactor coil is de-energised; the timing period runs from the instant of coil drop-out. The permissible short-time rating allows 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms at 60 °C — relevant for inrush loads like solenoid valves or small motor starters.

MPN