Schneider Electric LC1D80004F7 4-Pole Contactor, 125 A AC-1

MPN LC1D80004F7
Active

Schneider Electric TeSys Deca, 4-pole contactor, 125 A AC-1 resistive load, AC 50/60 Hz coil, 4 NO power poles, motor power 22–55 kW across 220–500 V.

$705.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1D80004F7 key specifications
ParameterValue
Control circuit typeAC 50/60 Hz
Main product or component typeContactor
VoltagePower circuit Power circuit <= 690 V AC
Coil voltage110 V AC 50/60 Hz
Current125 A (at 80 A (at 80 A (at 55 A (at <140 °F (60 °C)) at <= 400 V AC AC-4 for power circuit
Breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
Utilization categoryAC-1
IP ratingIP20
Temp operating max60 °C
Temp operating min-40 °C
Pollution degree3
Depth4.9 in (125 mm)

All specifications

LC1D80004F7 additional specifications
ParameterValue
Width3.8 in (96 mm)
Height5 in (127 mm)
Electrical life cycles0.8 Mcycles 125 A AC-1 <= 440 V
Mechanical life cycles4 Mcycles
ApplicationResistive load
Fire behaviorV1 conforming to UL 94
Operating time20...35 ms closing 6...20 ms opening
Permissible ambient air temperature around the device-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating

Product details

Its AC-1 utilisation category rates it for 125 A resistive loads, and the motor power table covers induction motors from 22 kW at 230 V up to 55 kW at 500 V. The coil is AC 50/60 Hz without a built-in suppressor module; external suppression is required if switching inductive control circuits. Coil hold power is 245 VA inrush at 20 °C, steady-state heat dissipation 6–10 W.

The contactor carries certifications under IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14, and UL 60947-4-1, so it meets North American and international standards for industrial control equipment.

Mounts on a plate or 35 mm DIN rail. Power circuit wiring accepts 4–50 mm² flexible with cable end, and tightening torque is 106.2 lbf·in (12 N·m) for the power terminals. Mechanical durability is 4 million cycles, electrical durability 0.8 million cycles at 125 A AC-1, 440 V. Maximum operating rate is 3600 cycles per hour at 60 °C.

MPN