Skip to main content
Schneider Electric LC1F1400MD

TeSys F LC1F1400MD Contactor, 1400 A AC-1, 220 V DC Coil

MPN LC1F1400MD
Obsolete

Schneider Electric TeSys F LC1F1400MD, 3-pole contactor, 1400 A AC-1, 220 V DC coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F1400MD key specifications
ParameterValue
Control circuit typeDC standard
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage220 V DC
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1
Current1400 A (at <40 °C) AC AC-1
Breaking capacity2100 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max40 °C
Temp operating min-5 °C

All specifications

LC1F1400MD additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth238.6 mm
Width438 mm
Height332 mm
ApplicationResistive load
Operating time50...60 ms closing 45...60 ms opening
Operating temperature-5...40 °C
Permissible ambient air temperature around the device-40...60 °C

Product details

What the 1400 A AC-1 rating means for your BOM line

The Schneider Electric TeSys F LC1F1400MD is a 3-pole contactor rated 1400 A in AC-1 duty (resistive load) at ≤40 °C. The coil is 220 V DC standard, with a hold-in draw of 10 W at 20 °C and an inrush peak of 2100 W. For a sourcing buyer checking fit: this is a plate-mount part (438 mm wide, 332 mm high, 238.6 mm deep), not a DIN-rail snap-on, so panel cutout and busbar planning are required.

AC-1 duty and the resistive load curve

Rated 1400 A in AC-1 (resistive load) — this is the contactor's full thermal current rating. The associated fuse is 1600 A gG at ≤440 V. Short-time withstand (Icw) is 8000 A for 10 s, 6000 A for 30 s, and 4500 A for 1 min at 40 °C. Power dissipation per pole is 150 W in AC-1, total 10 W coil hold-in. For a panel OEM: the 58 N.m power-circuit tightening torque and bar connection (busbar cross-section 100 x 5 mm) tell you this is a bolted-busbar installation, not a lug-and-cable job.

Integration — plate mount, bolted busbar, control wiring

Mounts on a plate (not DIN rail). Power circuit uses bolted bar connections — busbar cross-section 100 x 5 mm, two cables. Control circuit uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid (with or without ferrule). Tightening torque: control circuit 1.2 N.m, power circuit 58 N.m. Storage temperature range -60 to 80 °C; operating ambient -5 to 40 °C. Overvoltage category III, rated impulse withstand 8 kV.

MPN
LC1F1400MD