Skip to main content
Schneider Electric LC1F150P5

Schneider Electric LC1F150P5 TeSys F Contactor, 250 A AC-3,

MPN LC1F150P5
Obsolete

Schneider Electric TeSys F series, LC1F150P5, 3-pole contactor, 250 A rated operational current (AC-3), 230 V AC 50 Hz coil, plate mount, 171 x 163.5 x 170 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F150P5 key specifications
ParameterValue
Control circuit typeAC at 50 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage230 V AC 50 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current250 A (at 150 A (at <55 °C) at <= 440 V AC-3
Breaking capacity1200 A conforming to IEC 60947-4-1
Utilization categoryAC-4 AC-1 AC-3
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-40 °C

All specifications

LC1F150P5 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth171 mm
Width163.5 mm
Height170 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load, Motor control
Operating time23...35 ms closing 5...15 ms opening
Operating temperature-40...60 °C
Permissible ambient air temperature around the device60...70 °C at Uc

Product details

The LC1F150P5: The 250 A AC-3 rating governs motor switching — that's the current the contactor can make and break across a typical induction motor load. For resistive heating (AC-1), the thermal current Ith is 250 A at 50 Hz, with 22 W dissipation per pole. The 0.35 mOhm average impedance per pole at 250 A gives a voltage drop worth checking against your load's minimum operating voltage.

Plate-mounted, not DIN-rail — plan for a drilled backplate or sub-panel. Dimensions are 171 mm deep, 163.5 mm wide, 170 mm tall. Power connections accept bar (25 x 3 mm busbar), ring lugs up to 120 mm², or bolted connection. Control wiring uses screw clamp terminals, 1 to 4 mm² flexible or solid. Torque power circuit connections to 18 N·m, control circuit to 1.2 N·m. Front face with shrouds achieves IP2X.

Standards and Environmental Range

Certified to IEC 60947-4-1 and EN 60947-4-1, the standard for contactors and motor-starters. Rated insulation voltage is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C. Overvoltage category III suits fixed-installation distribution panels. Protective treatment is TH (tropicalized) for humid environments.

MPN
LC1F150P5