Skip to main content
Schneider Electric LC1F185D7

LC1F185D7 TeSys F Contactor, 185 A AC-3, 42 V AC Coil

MPN LC1F185D7
Obsolete

Schneider Electric TeSys F contactor, LC1F185D7, 3-pole, 185 A AC-3 at ≤440 V, 42 V AC 40-400 Hz coil, 90 kW at 380-400 V AC-3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F185D7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage690 V AC 50/60 Hz
Coil voltage42 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current275 A (at 185 A (at <55 °C) at <= 440 V AC-3
Breaking capacity1480 A conforming to IEC 60947-4-1
Utilization categoryAC-4 AC-3 AC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C

All specifications

LC1F185D7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth181 mm
Width168.5 mm
Height174 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control
Operating time20...35 ms closing 7...15 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The LC1F185D7 is a 3-pole TeSys F contactor from Schneider Electric, rated for switching motor loads up to 185 A in AC-3 duty (≤440 V) — that's the current it can make and break under the inductive load of a squirrel-cage motor during starting and running. At 380-400 V AC, that translates to 90 kW motor power; at 415 V it handles 100 kW, and at 500 V it still delivers 110 kW. The 42 V AC control coil (40-400 Hz) pulls 1070 VA inrush and holds at 9.9 VA, with a dropout range of 0.2-0.55 Uc — useful to know if you're integrating into a control transformer circuit with voltage sag. The contactor also carries AC-1 (resistive load) and AC-4 (plugging/inching) ratings, with a rated breaking capacity of 1480 A per IEC 60947-4-1. The 0.33 mOhm average impedance at 275 A Ith means heat dissipation runs 8-9.8 W total, or 12 W per pole in AC-3 and 25 W per pole in AC-1 — factor that into your panel thermal budget.

This part is end-of-life hot (EOL hot) — Schneider has discontinued production and the last-time-buy window is closed or closing.

Mounts to a plate (not DIN rail), with dimensions 174 mm high x 168.5 mm wide x 181 mm deep. Power circuit connections accept bar (25 x 3 mm busbar), ring terminals up to 150 mm², or bolted connections. Control circuit uses screw clamp terminals accepting 1-4 mm² flexible or solid. Tightening torque: 18 N.m on power, 1.2 N.m on control. IP2X on the front face with shrouds per IEC 60529.

Designed to IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage 1000 V per IEC 60947-4-1, overvoltage category III. Protective treatment TH (tropicalized). Operating altitude 3000 m without derating, ambient temperature -5 to 55 °C operation, -60 to 80 °C storage.

MPN