Skip to main content
Schneider Electric LC1F185FE5

Schneider Electric LC1F185FE5 TeSys F Contactor, 275 A, 115

MPN LC1F185FE5
Obsolete

Schneider Electric TeSys F, LC1F185FE5, 3-pole contactor, 275 A rated operational current (AC-3), 115 V AC 50 Hz coil, plate mount, 181 mm depth.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F185FE5 key specifications
ParameterValue
Control circuit typeAC at 50 Hz
Main product or component typeContactor
Voltage690 V AC 50/60 Hz
Coil voltage115 V AC 50 Hz
Current275 A (at 185 A (at <55 °C) at <= 440 V AC-3
Breaking capacity1480 A conforming to IEC 60947-4-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-60...80 °C
Depth181 mm

All specifications

LC1F185FE5 additional specifications
ParameterValue
Width168.5 mm
Height174 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control
Operating time20...35 ms closing 7...15 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric LC1F185FE5 is a 3-pole TeSys F contactor with a 115 V AC 50 Hz coil, rated for 275 A operational current in AC-3 duty (motor switching) and built to IEC 60947-4-1. It handles motor loads up to 90 kW at 380–400 V and 110 kW at 500 V AC-3, making it a fit for medium-voltage motor control centers and heavy conveyor or pump drives. Plate-mount construction means it lands on a backplate or sub-panel, not a DIN rail — plan the enclosure layout accordingly.

The AC-1 rating (resistive load) is higher, but for motor duty, stick with the AC-3 figure. Mechanical durability is 10 million cycles, so in a moderate-duty application (one or two operations per minute) it'll outlast the panel. Coil hold-in power is 55 VA at 50 Hz; the inrush is 805 VA — ensure your control transformer can handle that surge on pickup.

Integration notes — plate mount, wiring, environment

Mounts on a plate (not DIN rail). Power circuit terminals accept bar (25 x 3 mm busbar), ring lugs up to 150 mm², or connectors for 150 mm² cable. Control circuit uses screw clamp terminals, 1–4 mm² flexible or solid. Torque: 18 N·m on power, 1.2 N·m on control. Altitude rating is 3000 m without derating. IP2X front face with shrouds — not washdown-rated, so keep it in a cabinet.

MPN
LC1F185FE5