Schneider Electric LC1F185V5 TeSys F Contactor, 275 A AC-3,

MPN LC1F185V5
Obsolete

Schneider Electric TeSys F, LC1F185V5, 3-pole contactor, 275 A AC-3 rated operational current, 400 V AC 50 Hz coil, plate mount, EOL phase.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F185V5 key specifications
ParameterValue
Control circuit typeAC at 50 Hz
Main product or component typeContactor
Voltage690 V AC 50/60 Hz
Coil voltage400 V AC 50 Hz
Current275 A (at 185 A (at <55 °C) at <= 440 V AC-3
Breaking capacity1480 A conforming to IEC 60947-4-1
Utilization categoryAC-3 AC-1 AC-4
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-60...80 °C

All specifications

LC1F185V5 additional specifications
ParameterValue
Depth181 mm
Width168.5 mm
Height174 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load, Motor control
Operating time20...35 ms closing 7...15 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric LC1F185V5 is a TeSys F series 3-pole contactor rated for 275 A operational current in AC-3 duty (motor switching) and carries a 400 V AC 50 Hz control coil. It is designed for plate mounting and handles motor loads up to 90 kW at 380–400 V AC, 100 kW at 415 V, and 110 kW at 500 V or 660–690 V — figures that cover most European and Asian industrial voltages in one part.

The AC-1 rating (resistive load) will be higher, but for motor control, AC-3 is the spec to match to your motor FLA. The coil is 400 V AC 50 Hz only — not a dual-voltage or DC coil — so the control circuit must supply that exactly. Drop-out occurs between 0.35 and 0.55 Uc (140–220 V), which is a standard margin for AC coils.

Mounts on a plate (not DIN rail), so panel layout needs to account for bolted-down installation. Power connections accept bar (25 x 3 mm busbar), ring lugs up to 150 mm², or bolted connection — flexible for high-current cabling. Control circuit uses screw clamp terminals accepting 1–4 mm² flexible or solid. The front face achieves IP2X with shrouds fitted, which is basic finger protection for the panel interior. Dimensions are 174 mm high, 168.5 mm wide, 181 mm deep — a substantial frame that needs clearance for cable bending radius on 150 mm² conductors.

Certified to IEC 60947-4-1 and EN 60947-4-1 (the contactor standard for motor starters), plus IEC 60947-1 and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, with overvoltage category III. The TH protective treatment indicates tropicalised coating for humid environments. Associated fuse ratings are 200 A aM or 315 A gG at ≤ 440 V — useful for coordination with upstream short-circuit protection.