Schneider Electric LC1F185V5 — Contactors

Schneider Electric LC1F185V5 TeSys F Contactor, 275 A AC-3,

MPNLC1F185V5
Obsolete

Schneider Electric TeSys F, LC1F185V5, 3-pole contactor, 275 A AC-3 rated operational current, 400 V AC 50 Hz coil, plate mount, EOL phase.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F185V5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load

Ratings & Performance

LC1F185V5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 690 V AC 50/60 Hz
Utilisation categoryAC-3 AC-1 AC-4

Contacts & Poles

LC1F185V5 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F185V5 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F185V5 — Approvals
ParameterValue
StandardsEN 60947-4-1 IEC 60947-4-1 JIS C8201-4-1 IEC 60947-1 EN 60947-1

Mechanical

LC1F185V5 — Mechanical
ParameterValue
Width168.5 mm
Height174 mm
Depth181 mm

Product details

The Schneider Electric LC1F185V5 is a TeSys F series 3-pole contactor rated for 275 A operational current in AC-3 duty (motor switching) and carries a 400 V AC 50 Hz control coil. It is designed for plate mounting and handles motor loads up to 90 kW at 380–400 V AC, 100 kW at 415 V, and 110 kW at 500 V or 660–690 V — figures that cover most European and Asian industrial voltages in one part.

The AC-1 rating (resistive load) will be higher, but for motor control, AC-3 is the spec to match to your motor FLA. The coil is 400 V AC 50 Hz only — not a dual-voltage or DC coil — so the control circuit must supply that exactly. Drop-out occurs between 0.35 and 0.55 Uc (140–220 V), which is a standard margin for AC coils.

Mounts on a plate (not DIN rail), so panel layout needs to account for bolted-down installation. Power connections accept bar (25 x 3 mm busbar), ring lugs up to 150 mm², or bolted connection — flexible for high-current cabling. Control circuit uses screw clamp terminals accepting 1–4 mm² flexible or solid. The front face achieves IP2X with shrouds fitted, which is basic finger protection for the panel interior. Dimensions are 174 mm high, 168.5 mm wide, 181 mm deep — a substantial frame that needs clearance for cable bending radius on 150 mm² conductors.

Certified to IEC 60947-4-1 and EN 60947-4-1 (the contactor standard for motor starters), plus IEC 60947-1 and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, with overvoltage category III. The TH protective treatment indicates tropicalised coating for humid environments. Associated fuse ratings are 200 A aM or 315 A gG at ≤ 440 V — useful for coordination with upstream short-circuit protection.

Frequently asked questions

How do I get current pricing and availability for LC1F185V5?

Pricing and availability are confirmed at quote time against an RFQ. We source this EOL part through independent distribution channels; submit an RFQ and we will return current market pricing and confirmed stock position.

What is the closest alternative to LC1F185V5 in the TeSys F family?

There is no official successor order code listed for this part. For a new design, consult the current TeSys F catalogue for an active equivalent with similar 275 A AC-3 rating and 400 V AC coil. For an installed base, the LC1F185V5 remains the correct service part while stock lasts.

What motor power can LC1F185V5 handle?

It handles 90 kW at 380–400 V AC, 100 kW at 415 V and 440 V, 110 kW at 500 V and 660–690 V, and 55 kW at 220–230 V — all in AC-3 duty (standard motor starting).

What compliance documentation does LC1F185V5 carry?

It is certified to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 with overvoltage category III. The TH treatment indicates tropicalised protection for humid environments.

MPN