Skip to main content
Schneider Electric LC1F185V7

Schneider TeSys LC1F185V7 Contactor, 90 kW AC-3, 400 V Coil

MPN LC1F185V7
Obsolete

Schneider Electric TeSys F LC1F185V7, 3-pole contactor, 90 kW at 380-400 V AC-3, 400 V AC 50/60 Hz coil, plate mount, 275 A rated operational current.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F185V7 key specifications
ParameterValue
Motor starter typeDirect on-line contactor
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage690 V AC 50/60 Hz
Coil voltage400 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current275 A (at 185 A (at <55 °C) at <= 440 V AC-3
Breaking capacity1480 A conforming to IEC 60947-4-1
Utilization categoryAC-3 AC-4 AC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C

All specifications

LC1F185V7 additional specifications
ParameterValue
Temp operating min-5 °C
Storage temperature-60...80 °C
Depth181 mm
Width168.5 mm
Height174 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load, Motor control
Operating time35 ms closing at Uc) 130 ms opening at Uc)
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric TeSys F LC1F185V7 is a 3-pole, direct on-line contactor rated for switching motor loads up to 90 kW at 380-400 V AC in AC-3 duty (cites:). The 400 V AC coil pulls in at 0.85 to 1.1 times its rated control voltage and drops out between 0.2 and 0.55 Uc (cites:). Rated operational current is 275 A at 185 A in AC-3 at ≤ 440 V (cites:). Mounts to a plate (cites:). The power circuit accepts bar connections (25 x 3 mm busbar), ring terminals, or bolted lugs for 150 mm² cable (cites:). Control wiring uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid (cites:). Tightening torque is 18 N.m on the power side, 1.2 N.m on the control side (cites:).

At 415 V it delivers 100 kW, at 440 V also 100 kW, and at 500 V it reaches 110 kW (cites:). For AC-4 duty (plugging, inching) the rating drops to 33 kW at 400 V — that is the reversing or jogging limit, not the continuous running load (cites:). The utilisation categories (AC-3, AC-4, AC-1) are certified to IEC 60947-4-1 (cites:,). Rated breaking capacity is 1480 A conforming to IEC 60947-4-1 (cites:). The associated fuse recommendation is 200 A aM or 315 A gG at ≤ 440 V (cites:). Mechanical durability is 10 million cycles (cites:). Maximum operating rate is 2400 cycles per hour at 55 °C (cites:). Heat dissipation runs 8 to 9.8 W total, with 12 W per pole in AC-3 and 25 W per pole in AC-1 (cites:,).

Designed and tested to IEC 60947-4-1, IEC 60947-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1 (cites:). Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C (cites:). Overvoltage category III (cites:). IP2X front face with shrouds per IEC 60529 and VDE 0106 (cites:). Protective treatment TH for tropical environments (cites:).

MPN
LC1F185V7