Skip to main content
Schneider Electric LC1F185V7 — Contactors

Schneider TeSys LC1F185V7 Contactor, 90 kW AC-3, 400 V Coil

MPNLC1F185V7
Obsolete

Schneider Electric TeSys F LC1F185V7, 3-pole contactor, 90 kW at 380-400 V AC-3, 400 V AC 50/60 Hz coil, plate mount, 275 A rated operational current.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F185V7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC1F185V7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 690 V AC 50/60 Hz
Utilisation categoryAC-3 AC-4 AC-1
LC1F185V7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1F185V7 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F185V7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 JIS C8201-4-1 IEC 60947-1 EN 60947-1 EN 60947-4-1
LC1F185V7 — Mechanical
ParameterValue
Width168.5 mm
Height174 mm
Depth181 mm

Product details

The Schneider Electric TeSys F LC1F185V7 is a 3-pole, direct on-line contactor rated for switching motor loads up to 90 kW at 380-400 V AC in AC-3 duty (cites:). The 400 V AC coil pulls in at 0.85 to 1.1 times its rated control voltage and drops out between 0.2 and 0.55 Uc (cites:). Rated operational current is 275 A at 185 A in AC-3 at ≤ 440 V (cites:). Mounts to a plate (cites:). The power circuit accepts bar connections (25 x 3 mm busbar), ring terminals, or bolted lugs for 150 mm² cable (cites:). Control wiring uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid (cites:). Tightening torque is 18 N.m on the power side, 1.2 N.m on the control side (cites:).

At 415 V it delivers 100 kW, at 440 V also 100 kW, and at 500 V it reaches 110 kW (cites:). For AC-4 duty (plugging, inching) the rating drops to 33 kW at 400 V — that is the reversing or jogging limit, not the continuous running load (cites:). The utilisation categories (AC-3, AC-4, AC-1) are certified to IEC 60947-4-1 (cites:,). Rated breaking capacity is 1480 A conforming to IEC 60947-4-1 (cites:). The associated fuse recommendation is 200 A aM or 315 A gG at ≤ 440 V (cites:). Mechanical durability is 10 million cycles (cites:). Maximum operating rate is 2400 cycles per hour at 55 °C (cites:). Heat dissipation runs 8 to 9.8 W total, with 12 W per pole in AC-3 and 25 W per pole in AC-1 (cites:,).

Designed and tested to IEC 60947-4-1, IEC 60947-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1 (cites:). Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C (cites:). Overvoltage category III (cites:). IP2X front face with shrouds per IEC 60529 and VDE 0106 (cites:). Protective treatment TH for tropical environments (cites:).

Frequently asked questions

What is the closest alternative to LC1F185V7?

There is no official successor order code listed. For a current-production equivalent, a Schneider TeSys F contactor with the same frame size and coil voltage but an active lifecycle status would be the functional match — verify the AC-3 current rating and mounting footprint against the BOM.

What is LC1F185V7's motor power rating?

90 kW at 380-400 V AC in AC-3 duty (cites:). At 415 V and 440 V it delivers 100 kW, and at 500 V it reaches 110 kW (cites:). For AC-4 (reversing/jogging) the rating is 33 kW at 400 V (cites:).

Where can I buy LC1F185V7?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What compliance documentation does Schneider provide for LC1F185V7?

The contactor is certified to IEC 60947-4-1, IEC 60947-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1 (cites:). Rated insulation voltage is 1000 V per IEC and 1500 V per VDE 0110 group C (cites:). Overvoltage category III (cites:).

MPN