Skip to main content
Schneider Electric LC1F2100F7

Schneider Electric LC1F2100F7 TeSys F Contactor, 2100 A AC-1

MPN LC1F2100F7
Obsolete

Schneider Electric TeSys F LC1F2100F7, 3-pole contactor, 2100 A AC-1, 110 V AC 40-400 Hz control circuit, plate mount, EOL lifecycle.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F2100F7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage110 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1
Current2100 A (at <40 °C) AC AC-1
Breaking capacity3150 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max40 °C
Temp operating min-5 °C

All specifications

LC1F2100F7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth238.6 mm
Width438 mm
Height332 mm
ApplicationResistive load
Operating time100...170 ms opening 40...75 ms closing
Operating temperature-5...40 °C
Permissible ambient air temperature around the device-40...60 °C

Product details

The LC1F2100F7 is a 3-pole TeSys F contactor rated for 2100 A conventional free-air thermal current (Ith) and 2100 A operational current in AC-1 utilisation category — meaning it is sized for resistive heating loads, not motor starting. AC-1 duty covers loads where the current waveform stays nearly sinusoidal with no significant inrush, such as large electric furnaces, banked heaters, or power-factor correction capacitor banks. The 110 V AC control circuit (40-400 Hz) draws 2200 VA inrush and holds at 36 VA; dropout occurs between 0.3 and 0.5 Uc, so the coil reliably releases below about 55 V AC. Rated breaking capacity is 3150 A per IEC 60947-4-1, and the short-time withstand current (Icw) reaches 10 kA for 10 seconds — enough to coordinate with upstream 2000 A gG fuses at ≤ 440 V without nuisance opening during a downstream fault. The contactor carries overvoltage category III and an impulse withstand voltage of 8 kV, so it suits fixed-installation distribution panels where transient overvoltages from the mains are expected.

The contactor is certified to IEC 60947-4-1, EN 60947-1, EN 60947-4-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. The protective treatment (TH) indicates suitability for tropical/humid environments. Operating altitude reaches 3000 m without derating.

Mounts on a plate (not DIN rail) — the 438 mm width and 332 mm height require a dedicated backplate in the enclosure. Power connections use bolted bars accepting up to 100 x 5 mm busbars; control circuit connections are screw-clamp terminals accepting 1…4 mm² flexible or solid wire. Tightening torque is 58 N.m on the power circuit and 1.2 N.m on the control circuit. Heat dissipation is 36 W total (200 W per pole in AC-1), so forced ventilation or derating may be needed in a sealed cabinet above 40 °C ambient.

MPN
LC1F2100F7