Skip to main content
Schneider Electric LC1F500FE7

Schneider Electric TeSys F LC1F500FE7 Contactor, 700 A AC-3,

MPN LC1F500FE7
Obsolete

Schneider Electric TeSys F series, LC1F500FE7, 3-pole contactor, 700 A AC-3 rated operational current, 115 V AC 50/60 Hz coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F500FE7 key specifications
ParameterValue
Motor starter typeDirect on-line contactor
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage115 V AC 40...400 Hz
Current700 A (at 500 A (at <55 °C) at <= 440 V AC AC-3
Breaking capacity4000 A conforming to IEC 60947-4-1
Utilization categoryAC-1 AC-4 AC-3
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C

All specifications

LC1F500FE7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth232 mm
Width233 mm
Height238 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load, Motor control
Operating time40...65 ms closing 100...170 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

TeSys F contactor — LC1F500FE7, 700 A AC-3, 115 VAC coil

The Schneider Electric TeSys F LC1F500FE7 is a 3-pole contactor rated for 700 A operational current in AC-3 duty (motor switching) at ≤ 440 V, with a 115 V AC 50/60 Hz coil. It switches motor loads up to 250 kW at 380–400 V AC-3, and up to 355 kW at 500 V AC-3. Plate-mounted, IP20 front face with shrouds per IEC 60529.

Across the voltage band, AC-3 motor power ranges from 147 kW at 220–230 V up to 355 kW at 500 V. The AC-4 rating (reversing / inching duty) is lower: 80 kW at 400 V. The 115 V AC coil pulls 1100 VA inrush at 20 °C, with a hold dropout band of 0.3–0.5 Uc.

Designed to IEC 60947-4-1 and EN 60947-4-1 for contactors and motor-starters. Rated insulation voltage 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C. Overvoltage category III. IP20 front face with shrouds. Protective treatment TH (tropicalized).

Plate-mounted — not DIN-rail snap-on. Power circuit connections via bar (busbar cross-section 40 x 5 mm), lugs-ring terminals (2 cables 240 mm²), or bolted connection. Control circuit uses screw clamp terminals accepting 1–4 mm² flexible or solid. Tightening torque: 35 N·m on power circuit, 1.2 N·m on control circuit.

MPN
LC1F500FE7