Schneider Electric LC1F6304P7

Schneider LC1F6304P7 TeSys F Contactor, 1000 A AC-1, 4 NO, 2

MPN LC1F6304P7
Obsolete

Schneider Electric TeSys F, LC1F6304P7, 4-pole contactor, 1000 A AC-1, 230 V AC 40-400 Hz coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F6304P7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage230 V AC 40...400 Hz
Current1000 A (at <40 °C) at <= 440 V AC AC-1
Breaking capacity5040 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-60...80 °C

All specifications

LC1F6304P7 additional specifications
ParameterValue
Depth255 mm
Width389 mm
Height304 mm
Mechanical life cycles5 Mcycles
ApplicationResistive load
Operating time40...80 ms closing 100...200 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric LC1F6304P7 is a TeSys F 4-pole contactor rated for 1000 A in AC-1 utilisation category at ≤440 V, 40 °C — meaning it is sized for switching resistive loads such as large heating banks or furnace elements, not motor starting. The 230 V AC coil (40–400 Hz) draws 1650 VA inrush and 22 VA hold-in. Four normally-open power poles handle the full current path. Mounts on a plate (not DIN rail), with power connections via busbar (60 x 5 mm cross-section) or bolted connection. The IP20 front face with shrouds meets IEC 60529 and VDE 0106 for finger-safe panel integration. Rated breaking capacity is 5040 A per IEC 60947-4-1, and the rated insulation voltage is 1000 V (IEC 60947-4-1) or 1500 V (VDE 0110 Group C). Impulse withstand voltage is 8 kV, overvoltage category III.

The 1000 A AC-1 rating governs the continuous resistive load it can carry. For comparison, a motor load (AC-3) would derate significantly — this contactor is not selected for motor duty. The 4 NO pole configuration means all four poles switch the line; there are no built-in auxiliary contacts, so an external auxiliary block is needed for control-circuit feedback. Associated fuse rating is 1000 A gG or 630 A aM at ≤440 V — the gG (general-purpose) fuse protects against overload and short-circuit; the aM (motor-circuit) fuse is for backup protection only. The 5 Mcycle mechanical durability and 1200 cycles/hour maximum operating rate at 55 °C indicate a heavy-duty switching schedule for process applications. Operating time is 40–80 ms closing, 100–200 ms opening. Heat dissipation is 20 W total (120 W per pole in AC-1).

Physical integration and wiring

Dimensions: 389 mm wide, 304 mm high, 255 mm deep. Plate-mounted — ensure the backplate has clearance for the 255 mm depth plus busbar connections. Power circuit tightening torque is 58 N.m; control circuit is 1.2 N.m. Control wiring accepts 1–4 mm² flexible or solid, with or without ferrules, via screw clamp terminals. Altitude derating begins above 3000 m. The TH protective treatment indicates the contactor is suitable for tropical/humid environments.

MPN