Skip to main content
Schneider Electric LC1F7804P7

Schneider LC1F7804P7 TeSys F Contactor, 1600 A AC-1, 4 NO, 2

MPN LC1F7804P7
Obsolete

Schneider Electric TeSys F LC1F7804P7, 4-pole contactor, 1600 A AC-1, 230 VAC 40-400 Hz coil, 4 NO, plate mount, EOL phase-out.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F7804P7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage230 V AC 40...400 Hz
Current1600 A (at <40 °C) at <= 440 V AC AC-1
Breaking capacity6240 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-60...80 °C

All specifications

LC1F7804P7 additional specifications
ParameterValue
Depth255 mm
Width862 mm
Height434 mm
Mechanical life cycles5 Mcycles
ApplicationResistive load
Operating time40...80 ms closing 130...230 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

1600 A AC-1 Contactor — What This Rating Means

The Schneider Electric LC1F7804P7 is a TeSys F 4-pole contactor rated 1600 A in AC-1 utilisation category at ≤ 440 V, meaning it is sized for switching resistive heating loads, lighting banks, or transformer primaries — not motor starts. The AC-1 rating governs the continuous current the main poles carry without derating; for motor duty (AC-3), the same contactor would be rated significantly lower. The 4 NO power pole configuration gives four normally-open main contacts, all rated for the full 1600 A. The 230 VAC control coil draws 2100 VA inrush at pickup, dropping to 50 VA hold-in — the inrush surge matters for control transformer sizing in the panel.

Mounting and Integration — Plate-Mount, Not DIN Rail

Mounting support is plate — this contactor does not snap onto a DIN rail. The footprint is substantial: 862 mm wide, 434 mm high, 255 mm deep. Power circuit connections use bolted busbars rated for 100 x 5 mm cross-section; control circuit connections are screw clamp terminals accepting 1 to 4 mm² flexible or solid wire. Tightening torque for power circuit connections is 58 N.m, control circuit 1.2 N.m.

Designed and certified to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage (Ui) is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C. Impulse withstand voltage (Uimp) is 8 kV, overvoltage category III. The protective treatment is TH for tropicalized environments — suitable for humid or corrosive atmospheres when panel conditions are controlled.

MPN