Skip to main content
Schneider Electric LC1K0901P5

Schneider LC1K0901P5 TeSys K Contactor, 9A AC-3, 230V 50Hz,

MPN LC1K0901P5
Obsolete

Schneider Electric TeSys K, Contactor, 3P, 9A AC-3/AC-3e, ≤440V, aux 1NC, coil 230V 50Hz, screw clamp terminals, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1K0901P5 specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-1 AC-4
IP ratingIP20
Temp storage max80 °C
Temp storage min-50 °C
Storage temperature-50...80 °C
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 9 A AC-3 at Ue 1.3 Mcycles 9 A AC-3e at Ue 0.16 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control

Product details

The Schneider Electric LC1K0901P5 is a TeSys K series 3-pole contactor rated for 9 A in AC-3 duty (motor switching) at up to 440 V, with a 230 V 50 Hz coil and a single normally-closed auxiliary contact. It's a compact panel-mount unit — 45 mm wide, 58 mm tall, 57 mm deep — designed for DIN-rail or plate mounting, and carries IP20 finger-safe protection per VDE 0106. The screw-clamp terminals accept solid or stranded wire from 0.34 to 4 mm², with a tightening torque range of 0.8 to 1.3 N·m.

The 9 A AC-3 rating is the key selection number — it tells you this contactor will switch a 3-phase induction motor drawing up to 9 A under full load, which corresponds to roughly 4 kW at 400 V. The AC-3e category extends that to energy-efficient motors with higher inrush. For resistive loads (AC-1), it handles 20 A, and for plugging/reversing duty (AC-4), it's rated at 54 A but with much shorter electrical life — 20,000 cycles vs 1.3 million for AC-3. The 1.3 W heat dissipation at rated coil hold-in means it won't cook adjacent components in a tightly packed enclosure, but the 30 VA inrush at 20 °C is worth noting for transformer-coupled control circuits. The contactor can operate at up to 3600 cycles per hour — fast enough for most conveyor or pump cycling applications. The coil operates reliably between 0.8 and 1.15 times nominal voltage, and drops out at 0.2 times nominal below 50 °C. Minimum switching capability is 5 mA at 17 V for the signalling circuit — important to verify if you're switching low-level PLC inputs through the aux contact.

MPN
LC1K0901P5