Skip to main content
Schneider Electric LC1K0901P5 — Contactors

Schneider LC1K0901P5 TeSys K Contactor, 9A AC-3, 230V 50Hz,

MPNLC1K0901P5
Obsolete

Schneider Electric TeSys K, Contactor, 3P, 9A AC-3/AC-3e, ≤440V, aux 1NC, coil 230V 50Hz, screw clamp terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K0901P5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC1K0901P5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-1 AC-4
LC1K0901P5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0901P5 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K0901P5 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
LC1K0901P5 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K0901P5 is a TeSys K series 3-pole contactor rated for 9 A in AC-3 duty (motor switching) at up to 440 V, with a 230 V 50 Hz coil and a single normally-closed auxiliary contact. It's a compact panel-mount unit — 45 mm wide, 58 mm tall, 57 mm deep — designed for DIN-rail or plate mounting, and carries IP20 finger-safe protection per VDE 0106. The screw-clamp terminals accept solid or stranded wire from 0.34 to 4 mm², with a tightening torque range of 0.8 to 1.3 N·m.

The 9 A AC-3 rating is the key selection number — it tells you this contactor will switch a 3-phase induction motor drawing up to 9 A under full load, which corresponds to roughly 4 kW at 400 V. The AC-3e category extends that to energy-efficient motors with higher inrush. For resistive loads (AC-1), it handles 20 A, and for plugging/reversing duty (AC-4), it's rated at 54 A but with much shorter electrical life — 20,000 cycles vs 1.3 million for AC-3. The 1.3 W heat dissipation at rated coil hold-in means it won't cook adjacent components in a tightly packed enclosure, but the 30 VA inrush at 20 °C is worth noting for transformer-coupled control circuits. The contactor can operate at up to 3600 cycles per hour — fast enough for most conveyor or pump cycling applications. The coil operates reliably between 0.8 and 1.15 times nominal voltage, and drops out at 0.2 times nominal below 50 °C. Minimum switching capability is 5 mA at 17 V for the signalling circuit — important to verify if you're switching low-level PLC inputs through the aux contact.

Frequently asked questions

What are the key ratings for this contactor?

The LC1K0901P5 is a 3-pole contactor rated 9 A in AC-3/AC-3e duty at up to 440 V, with a 230 V 50 Hz coil and one normally-closed auxiliary contact. It handles 20 A in AC-1 resistive load and 54 A in AC-4 plugging duty. Mechanical life is 10 million cycles; electrical life is 1.3 million cycles at AC-3.

What compliance documentation is available for this part?

The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It also meets IEC 60335-1 and IEC 60335-2-40 appliance standards, with V-1 flame retardance per UL 94.

How do I source the LC1K0901P5?

Since it is obsolete, we source it through surplus and broker channels against an RFQ. Submit a request with your quantity and target delivery window, and we will quote available inventory with condition verification.

MPN