Skip to main content
Schneider Electric LC1K1201B5

Schneider TeSys K LC1K1201B5 Contactor, 12A AC-3, 24V 50Hz C

MPN LC1K1201B5
Obsolete

Schneider Electric TeSys K series, LC1K1201B5, 3-pole contactor, 12 A AC-3/AC-3e, coil 24 V 50 Hz, 1 NC auxiliary contact.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1K1201B5 specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-1 AC-4
IP ratingIP20
Temp storage max80 °C
Temp storage min-50 °C
Storage temperature-50...80 °C
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 12 A AC-3 at Ue 1.3 Mcycles 12 A AC-3e at Ue 0.3 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control
Operating time10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing

Product details

The Schneider Electric TeSys K LC1K1201B5 is a 3-pole contactor rated for 12 A in AC-3 and AC-3e utilisation categories at up to 440 V, with a 24 V 50 Hz coil and one normally closed auxiliary contact. For resistive loads (AC-1), it carries 20 A, and for inching/plugging duty (AC-4) it handles 72 A, though at much lower electrical endurance.

AC-3 means switching a squirrel-cage motor during running — making and breaking currents up to 6× rated during start, but only the motor full-load current during stop. The 12 A figure corresponds roughly to a 5.5 kW motor at 400 V three-phase. If your load is resistive (heater, lighting), the AC-1 rating of 20 A applies instead, so you get more headroom. The AC-4 rating of 72 A exists but note the electrical endurance drops to 20,000 cycles at that level — it is meant for occasional inching or reversing, not continuous plugging duty. The 1 NC auxiliary contact is built in — no add-on block needed for a basic interlock or status feedback. If you need more aux contacts, the TeSys K range offers side-mounting auxiliary blocks, but those are separate order codes. The coil draws 30 VA inrush and 4.5 VA holding at 20 °C, which is modest — a standard 24 V 50 Hz control transformer can drive several of these in parallel.

The LC1K1201B5 carries approvals across the major industrial regions: EN/IEC 60947-4-1 (Europe), UL 60947-4-1 (US), CSA C22.2 No 60947-4-1 (Canada), and JIS C8201-4-1 (Japan). It also meets the glow-wire test requirements of IEC 60335-1 and the specific air-conditioning standard UL 60335-2-40 Annex JJ. The enclosure is IP20 finger-safe per VDE 0106, so it can be mounted in a panel without additional finger-duct covers as long as the busbars are also shielded. For safety-related applications, the B10d values are provided per EN/ISO 13849-1: 1,369,863 cycles under nominal load and 20,000,000 cycles under mechanical load only. This allows the contactor to be used in a safety-related control system up to a certain SIL/PL level, provided the rest of the circuit meets the architecture requirements.

The 45 mm width (3-module) fits standard enclosure rail spacing — three of these side by side occupy 135 mm of rail. Screw-clamp terminals accept 1.5 to 4 mm² solid or 0.75 to 4 mm² flexible wire, with a tightening torque of 0.8 to 1.3 N·m. Operating altitude is 2000 m without derating; above that, the dielectric strength and thermal dissipation need to be checked against the manufacturer's altitude derating curve.

MPN