TeSys Deca LP1D800046SW Contactor, 4P, 72 V DC, AC-1

MPN LP1D800046SW
Obsolete

Schneider Electric TeSys Deca LP1D800046SW, 4-pole contactor, 72 V DC coil, AC-1 resistive load, 125 A, IP20 front face.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LP1D800046SW key specifications
ParameterValue
Control circuit typeDC wide range
Main product or component typeContactor
VoltagePower circuit Power circuit <= 300 V DC
Coil voltage72 V DC
Current125 A (at 80 A (at 80 A (at 55 A (at <60 °C) at <= 400 V AC AC-4 for power circuit
Breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
Utilization categoryAC-1
IP ratingIP20
Temp operating max70 °C
Temp operating min-40 °C
Pollution degree3
Depth181 mm

All specifications

LP1D800046SW additional specifications
ParameterValue
Width96 mm
Height127 mm
Electrical life cycles0.8 Mcycles 125 A AC-1 at Ue <= 440 V
Mechanical life cycles4 Mcycles
ApplicationResistive load
Fire behaviorV1 conforming to UL 94
Time constant75 ms
Operating time6...20 ms opening 20...35 ms closing
Permissible ambient air temperature around the device-40...60 °C 60...70 °C with derating

Product details

It's designed for switching resistive heating elements, lighting banks, or other non-inductive loads in industrial control panels. The 72 V DC wide-range control coil means it can be driven directly from a 48 V or 72 V DC bus without an extra converter — something to check if your panel runs on a nominal 48 V battery-backed supply. Mounts on a rail or plate, and the IP20 front face keeps accidental contact out while letting it sit inside a standard enclosure.

The AC-1 utilisation category is the key rating here. The continuous thermal current (Ith) is 125 A at 50 Hz — that's the current it can carry continuously through the power circuit. For a resistive heater bank pulling 100 A, this contactor has headroom; for a motor start, you'd want an AC-3 rated unit instead. The 72 V DC coil draws 22 W inrush at 20 °C. That's the peak power to pull the contactor in; holding power is lower. No built-in suppressor module is included, so you'll need to add a flyback diode or RC snubber across the coil if your PLC output can't handle the inductive kickback. The operating time is 6 to 20 ms opening and 20 to 35 ms closing — fast enough for most sequencing, but if you need faster arc extinction on a DC load, factor in the opening delay.

Certified to CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 60947-4-1. That covers the main North American and IEC standards for contactors and motor starters. Flame retardance is V1 per UL 94, and fire resistance is 850 °C per IEC 60695-2-1 — so it won't propagate a flame if a fault heats it up.