Skip to main content
Schneider Electric LP1K12016BD3

Schneider Electric LP1K12016BD3 TeSys K Contactor, 12A, 24V

MPN LP1K12016BD3
Obsolete

Schneider Electric TeSys K contactor, 3P, 12 A AC-3/AC-3e at 440 V, 24 V DC coil with integral suppression, 1 NC auxiliary.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LP1K12016BD3 specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-1 AC-4
IP ratingIP2X
Temp storage max80 °C
Temp storage min-50 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-50...80 °C
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 12 A AC-3 at Ue 1.3 Mcycles 12 A AC-3e at Ue 0.3 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load, Motor control
Operating time30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
Operating temperature-25...50 °C

Product details

The LP1K12016BD3 is a 3-pole TeSys K contactor from Schneider Electric, rated 12 A in AC-3 and AC-3e utilisation categories at 440 V, with a 24 V DC coil that includes an integral suppression device. It carries one normally closed instantaneous auxiliary contact. This size fits into the compact TeSys K footprint — 45 mm wide, 58 mm high, 57 mm deep — and mounts to either a plate or DIN rail, so it slots into a standard control-panel layout without eating up extra rail space.

The AC-3 rating at 12 A / 440 V is the motor-switching figure that governs real-world use — it handles squirrel-cage motors up to roughly 5.5 kW at 400 V. The AC-1 resistive rating goes higher (20 A), but for motor loads the AC-3 number is the one to match against your BOM. Electrical durability is 1.3 million cycles at the AC-3 rating; mechanical durability is 10 million cycles, so this contactor is built for moderate-duty cycling applications like conveyors or small pumps.

This part is officially obsolete per the manufacturer. There is no listed direct successor order code in the evidence.

Installation and integration notes

Terminals accept ring lugs with a 7 mm outer diameter. The IP2X finger-safe front cover is built in.

MPN
LP1K12016BD3