Schneider Electric LV839069

LV839069 MasterPact MTZ2 800A 3P Drawout, 200kA Icu

MPN LV839069
Obsolete

Schneider Electric MasterPact MTZ2, LV839069, 800 A, 3-pole, drawout, breaking capacity, 200 kA Icu at 254 V AC 60 Hz, 16.8 x 17.5 x 17.3 in.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839069 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch4.5 in (115 mm)
Depth16.8 in (426.8 mm)
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles12500 cycles ANSI C37.50
ApplicationProtection
Safety category200 kA Icu 254 V AC 60 Hz ANSI C37.50 200 kA Icu 508 V AC 60 Hz ANSI C37.50 130 kA Icu 635 V AC 60 Hz ANSI C37.50 200 kA Icu 254 V AC 50 Hz ANSI C37.50 150 kA Icu 508 V AC 50 Hz ANSI C37.50 100 kA Icu 635 V AC 50 Hz ANSI C37.50

Product details

The LV839069 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 3-pole, rated 800 A at 40 °C. That 800 A line current is the continuous rating in a 104 °F ambient — the number you use for cable and bus sizing, not a peak or short-time figure. The breaking capacity code means it delivers 200 kA Icu at 254 V AC 60 Hz per ANSI C37.50, dropping to 130 kA at 635 V AC 60 Hz. For a buyer matching an existing switchboard spec, the drawout cradle and base-plate-rail mounting (connection pitch 4.5 in) are the mechanical fit check — the 17.5 in width and 16.8 in depth tell you whether it lands in the existing cell without a bucket rework.

What the interrupting ratings mean in practice

At 508 V AC 60 Hz the Icu is 200 kA; at 635 V AC 60 Hz it drops to 130 kA. The rated short-time withstand current (Icw) is 30 kA for 0.5 s per ANSI C37.50, which governs selectivity coordination with downstream breakers during a delayed trip. Integral instantaneous protection is set at 49.5 to 55.5 kA, and the maximum breaking time is 9 ms — fast enough to limit let-through energy on a high-fault bus. Mechanical durability is 12,500 cycles; electrical durability 2,800 cycles under ANSI C37.50 — numbers that matter for a breaker that sees regular switching, not just fault backup.