Schneider Electric LV839069 — Air Circuit Breakers

LV839069 MasterPact MTZ2 800A 3P Drawout, 200kA Icu

MPNLV839069
Obsolete

Schneider Electric MasterPact MTZ2, LV839069, 800 A, 3-pole, drawout, breaking capacity, 200 kA Icu at 254 V AC 60 Hz, 16.8 x 17.5 x 17.3 in.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV839069 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
ApplicationProtection
LV839069 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz
LV839069 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)30 kA 0.5 s ANSI C37.50
Breaking capacity codeL1
LV839069 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)12500 cycles ANSI C37.50
Electrical durability (cycles)2800 cycles ANSI C37.50
LV839069 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch4.5 in (115 mm)

Product details

The LV839069 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 3-pole, rated 800 A at 40 °C. That 800 A line current is the continuous rating in a 104 °F ambient — the number you use for cable and bus sizing, not a peak or short-time figure. The breaking capacity code means it delivers 200 kA Icu at 254 V AC 60 Hz per ANSI C37.50, dropping to 130 kA at 635 V AC 60 Hz. For a buyer matching an existing switchboard spec, the drawout cradle and base-plate-rail mounting (connection pitch 4.5 in) are the mechanical fit check — the 17.5 in width and 16.8 in depth tell you whether it lands in the existing cell without a bucket rework.

What the interrupting ratings mean in practice

At 508 V AC 60 Hz the Icu is 200 kA; at 635 V AC 60 Hz it drops to 130 kA. The rated short-time withstand current (Icw) is 30 kA for 0.5 s per ANSI C37.50, which governs selectivity coordination with downstream breakers during a delayed trip. Integral instantaneous protection is set at 49.5 to 55.5 kA, and the maximum breaking time is 9 ms — fast enough to limit let-through energy on a high-fault bus. Mechanical durability is 12,500 cycles; electrical durability 2,800 cycles under ANSI C37.50 — numbers that matter for a breaker that sees regular switching, not just fault backup.

Frequently asked questions

Where can I buy LV839069?

The part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

What is the interrupting rating of LV839069?

The LV839069 delivers 200 kA Icu at 254 V AC 60 Hz, 200 kA at 508 V AC 60 Hz, and 130 kA at 635 V AC 60 Hz, all per ANSI C37.50. The rated short-time withstand current (Icw) is 30 kA for 0.5 s.