Schneider Electric LV839075

Schneider Electric LV839075 MasterPact MTZ3, 3200 A, 3-Pole

MPN LV839075
Active

Schneider Electric MasterPact MTZ3, LV839075, 3-pole drawout circuit breaker, 3200 A at 40 °C, breaking capacity, 200 kA Icu at 254 V AC, without Micrologic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839075 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch9.06 in (230 mm)
Depth16.8 in (426.8 mm)
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Electrical life cycles1000 cycles ANSI C37.50
Mechanical life cycles10000 cycles ANSI C37.50
ApplicationProtection
Safety category200 kA Icu 254 V AC 60 Hz ANSI C37.50 200 kA Icu 508 V AC 60 Hz ANSI C37.50 130 kA Icu 635 V AC 60 Hz ANSI C37.50 200 kA Icu 254 V AC 50 Hz ANSI C37.50 150 kA Icu 508 V AC 50 Hz ANSI C37.50 100 kA Icu 635 V AC 50 Hz ANSI C37.50

Product details

The LV839075 is a MasterPact MTZ3 drawout circuit breaker rated 3200 A continuous at 40 °C — that's the full-frame current for a 3-pole ANSI breaker, sized for the main incoming feed or a large bus tie in a 635 V AC switchboard. The breaking capacity code delivers 200 kA Icu at 254 V AC 60 Hz per ANSI C37.50, stepping down to 130 kA at 635 V AC 60 Hz, so it safely interrupts fault currents up to utility-transformer levels without cascading upstream. Integral instantaneous protection is set at 243-297 kA, meaning the magnetic trip operates on a hard short rather than a moderate overload — selectivity with downstream feeders stays intact. The 100 kA Icw for 0.5 s (ANSI C37.50) gives the breaker short-time withstand for delayed-tripping coordination schemes, common in industrial distribution where you want the feeder breaker to clear first. This unit ships without a Micrologic trip unit, so the buyer specifies the protection curve separately — the breaker frame accepts the full Micrologic range (electronic, with or without display, for LSIG or LSI patterns). Mechanical durability is 10,000 cycles, electrical durability 1,000 cycles per ANSI C37.50, which is typical for a drawout air breaker used as a main or tie — not a daily-operating contactor, but built for decades of infrequent switching. The 9 ms maximum breaking time means arc extinction happens within one half-cycle at 60 Hz, limiting let-through energy for downstream equipment.

Drawout mounting on base plate rails — the breaker chassis slides into a fixed cradle, so the line and load connections stay in the switchgear while the breaker is racked out for maintenance or replacement. The connection pitch is 230 mm (9.06 in), matching standard ANSI drawout cubicle cutouts. Overall dimensions: 444.3 mm wide (17.5 in), 426.8 mm deep (16.8 in), 438.8 mm high (17.3 in) — verify the switchgear cell height clears the arc-chamber top, especially in older gear where the bus riser limits overhead space. Push-button control for local open/close; network type is AC, 50/60 Hz.

MPN
LV839075