Schneider Electric LV839075 — Air Circuit Breakers

Schneider Electric LV839075 MasterPact MTZ3, 3200 A, 3-Pole

MPNLV839075
Active

Schneider Electric MasterPact MTZ3, LV839075, 3-pole drawout circuit breaker, 3200 A at 40 °C, breaking capacity, 200 kA Icu at 254 V AC, without Micrologic trip unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV839075 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ3
ApplicationProtection

Electrical ratings

LV839075 — Electrical ratings
ParameterValue
Poles3P
Network typeAC
Network frequency50/60 Hz

Breaking & withstand capacity

LV839075 — Breaking & withstand capacity
ParameterValue
Rated short-time withstand current (Icw)100 kA 0.5 s ANSI C37.50
Breaking capacity codeL1

Performance

LV839075 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.70 ms
Mechanical durability (cycles)10000 cycles ANSI C37.50
Electrical durability (cycles)1000 cycles ANSI C37.50

Mechanical & connection

LV839075 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportBase plate Rails
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Depth16.8 in (426.8 mm)
Connection pitch9.06 in (230 mm)

Product details

The LV839075 is a MasterPact MTZ3 drawout circuit breaker rated 3200 A continuous at 40 °C — that's the full-frame current for a 3-pole ANSI breaker, sized for the main incoming feed or a large bus tie in a 635 V AC switchboard. The breaking capacity code delivers 200 kA Icu at 254 V AC 60 Hz per ANSI C37.50, stepping down to 130 kA at 635 V AC 60 Hz, so it safely interrupts fault currents up to utility-transformer levels without cascading upstream. Integral instantaneous protection is set at 243-297 kA, meaning the magnetic trip operates on a hard short rather than a moderate overload — selectivity with downstream feeders stays intact. The 100 kA Icw for 0.5 s (ANSI C37.50) gives the breaker short-time withstand for delayed-tripping coordination schemes, common in industrial distribution where you want the feeder breaker to clear first. This unit ships without a Micrologic trip unit, so the buyer specifies the protection curve separately — the breaker frame accepts the full Micrologic range (electronic, with or without display, for LSIG or LSI patterns). Mechanical durability is 10,000 cycles, electrical durability 1,000 cycles per ANSI C37.50, which is typical for a drawout air breaker used as a main or tie — not a daily-operating contactor, but built for decades of infrequent switching. The 9 ms maximum breaking time means arc extinction happens within one half-cycle at 60 Hz, limiting let-through energy for downstream equipment.

Drawout mounting on base plate rails — the breaker chassis slides into a fixed cradle, so the line and load connections stay in the switchgear while the breaker is racked out for maintenance or replacement. The connection pitch is 230 mm (9.06 in), matching standard ANSI drawout cubicle cutouts. Overall dimensions: 444.3 mm wide (17.5 in), 426.8 mm deep (16.8 in), 438.8 mm high (17.3 in) — verify the switchgear cell height clears the arc-chamber top, especially in older gear where the bus riser limits overhead space. Push-button control for local open/close; network type is AC, 50/60 Hz.

Frequently asked questions

Where can I buy LV839075 and how is it quoted?

The LV839075 is sourced to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time — no stock count or price figure is published here because the market price varies with volume and project terms.

What is the closest alternative to LV839075 in the MasterPact MTZ3 family?

There is no pin-compatible drop-in alternative because the 3200 A frame and breaking capacity (200 kA Icu at 254 V AC) define the physical cradle interface and arc-chamber size. A higher breaking capacity frame (H1 or H2) requires a different cell cutout and cannot be retrofitted into an cradle without switchgear modification.