Skip to main content
Schneider Electric LV846167

LV846167 MasterPact MTZ2 4000 A, 100 kA Circuit Breaker

MPN LV846167
Active

Schneider Electric MasterPact MTZ2, fixed circuit breaker, 3P, 4000 A at 40 °C, H2V 100 kA 415 V AC, IP30, EN/IEC 60947-1/2.

$14,989.40 – $16,099.56 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846167 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846167 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width422 mm
Height352 mm
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846167 is a MasterPact MTZ2 fixed circuit breaker, 3-pole, rated 4000 A at 40 °C, with a H2V performance level delivering 100 kA Icu at 440 V AC. It is a Category B breaker (selectivity category per IEC 60947-2), meaning it is designed for selective coordination in a distribution system — upstream faults clear without taking downstream circuits out. The 100 kA Icw for 1 second tells you it can pass that fault current until the upstream device clears, which is the whole point of a Category B breaker in a main or tie position.

Sizing and ratings for the BOM

That is unusual at this current level; many breakers have a lower Ics. The Icm (making capacity) is 220 kA at 440 V, which governs the first half-cycle peak the breaker must close into. Power dissipation is 650 W — factor that into panel ventilation if the breaker is enclosed.

Fixed mounting on rails or a base plate. Connection pitch is 115 mm. Both upside and downside connections accept front or rear terminations — choose based on your switchgear bus arrangement. The breaker is 422 mm wide, 352 mm high, 300 mm deep. IP30 enclosure protection; not rated for washdown, so keep it in a dry indoor switchgear lineup.

MPN
LV846167