Skip to main content
Schneider Electric LV846181

LV846181 MasterPact MTZ2 4P 1000A Circuit Breaker, 100 kA

MPN LV846181
Active

Schneider Electric MasterPacT MasterPact MTZ2, fixed 4P circuit breaker, LV846181, 1000 A at 40 °C, H2V 100 kA 415 V AC.

$14,447.73 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846181 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846181 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846181 is a Schneider Electric MasterPact MTZ2 fixed-mount, 4-pole circuit breaker rated 1000 A at 40 °C in the H2V performance class — 100 kA breaking at 415 V AC. It is built for main-feed protection in power-distribution switchboards where Category B selectivity and full-rated short-time withstand are required. The 100 kA Ics at 440 V AC means it clears a fault at that level and stays usable afterward, not just survives it once. That matters when you are coordinating downstream breakers in a plant main or a wind-turbine tower base.

The Icw of 100 kA for 0.5 s (75 kA for 3 s) tells you this breaker handles delayed tripping for full selectivity with downstream devices — you do not have to sacrifice coordination to get fault clearance. The Icm of 220 kA at 440 V AC confirms the making capacity on closing into a bolted fault. Electrical durability is 10 000 cycles at In under AC-23A (switching motor loads) and 6000 cycles under AC-3, so it is rated for regular switching duty, not just backup protection. That 70 W power dissipation at full load matters for enclosure heat rise — plan the ventilation.

Fixed-mount on rails or base plate, 537 mm wide by 352 mm high by 300 mm deep. Connection pitch is 115 mm. Both front and rear connections are available on upside and downside, so it fits switchboard bus-bar layouts without rework. Neutral is on the left.

Also complies with IEC 61557-12 for measuring and monitoring functions. Suitability for isolation is confirmed. Operating altitude 0–2000 m without derating, 2000–5000 m with derating — relevant for high-altitude installations or wind-turbine nacelles above 2000 m.

MPN
LV846181