Skip to main content
Schneider Electric LV846181 — Air Circuit Breakers

LV846181 MasterPact MTZ2 4P 1000A Circuit Breaker, 100 kA

MPNLV846181
Active

Schneider Electric MasterPacT MasterPact MTZ2, fixed 4P circuit breaker, LV846181, 1000 A at 40 °C, H2V 100 kA 415 V AC.

$14,447.73Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV846181 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV846181 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Sensor rating400 A 630 A 800 A 1000 A
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV846181 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 0.5 s 100 kA 1 s 75 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz
Performance typeH2V 100 kA 415 V AC
LV846181 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)15000 cycles with periodic preventive maintenance
Electrical durability (cycles)10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation70 W
LV846181 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportRails Base plate
Width537 mm
Height352 mm
Depth300 mm
Neutral pole positionLeft
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV846181 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV846181 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The LV846181 is a Schneider Electric MasterPact MTZ2 fixed-mount, 4-pole circuit breaker rated 1000 A at 40 °C in the H2V performance class — 100 kA breaking at 415 V AC. It is built for main-feed protection in power-distribution switchboards where Category B selectivity and full-rated short-time withstand are required. The 100 kA Ics at 440 V AC means it clears a fault at that level and stays usable afterward, not just survives it once. That matters when you are coordinating downstream breakers in a plant main or a wind-turbine tower base.

The Icw of 100 kA for 0.5 s (75 kA for 3 s) tells you this breaker handles delayed tripping for full selectivity with downstream devices — you do not have to sacrifice coordination to get fault clearance. The Icm of 220 kA at 440 V AC confirms the making capacity on closing into a bolted fault. Electrical durability is 10 000 cycles at In under AC-23A (switching motor loads) and 6000 cycles under AC-3, so it is rated for regular switching duty, not just backup protection. That 70 W power dissipation at full load matters for enclosure heat rise — plan the ventilation.

Fixed-mount on rails or base plate, 537 mm wide by 352 mm high by 300 mm deep. Connection pitch is 115 mm. Both front and rear connections are available on upside and downside, so it fits switchboard bus-bar layouts without rework. Neutral is on the left.

Also complies with IEC 61557-12 for measuring and monitoring functions. Suitability for isolation is confirmed. Operating altitude 0–2000 m without derating, 2000–5000 m with derating — relevant for high-altitude installations or wind-turbine nacelles above 2000 m.

Frequently asked questions

Who supplies LV846181 and how is it quoted for volume purchases?

The LV846181 is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is the closest alternative to LV846181 in the MasterPact family?

The MasterPact MTZ2 family includes multiple performance tiers (H1, H2, H2V). The LV846181 is the H2V 100 kA 4P 1000 A fixed variant. A lower-breaking variant (H1 or H2) would reduce fault-handling capacity; a higher-current frame or different pole count would change the footprint. No pin-compatible drop-in exists outside the MTZ2 platform.

What is LV846181's listed depth?

The LV846181 has a depth of 300 mm.

What is LV846181's listed range?

The LV846181 belongs to the MasterPacT range.

What compliance documentation does this breaker provide?

The LV846181 conforms to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2 and carries pollution degree 3 per IEC 60947-1.

MPN